Tools › Fluids and Heat Transfer › Thermodynamic Cycles › Thermodynamic Process Analyzer › Example
Throttling valve: saturated water at 1 MPa flashes to 15 % steam at 100 kPa
| Tool | Thermodynamic Process Analyzer |
| Source | original |
| Level | Undergraduate |
Problem
Saturated liquid water at 1 MPa passes through a valve to 100 kPa. How much of it turns to steam, how cold does it get, and how much entropy does the valve generate per kilogram?
Inputs to Enter
- Water and steam, throttling valve; state 1 by pressure and quality: 1,000 kPa, x = 0
- Exit pressure 100 kPa, mass flow 1 kg/s
Answers
- Constant enthalpy: h_2 = h_1 = 762.68 kJ/kg
- Flash fraction x_2 = (762.68 − 417.4)/2,258 = 0.1529; temperature falls from 179.89 °C to 99.61 °C
- Entropy generated 2.2288 − 2.1384 = 0.09032 kJ/(kg·K); lost work at 25 °C surroundings 26.93 kW per kg/s
Notes
Open this case in the tool: /analysis-tools/thermal-fluids/cycles/thermo-process-analyzer/?try=flashing-valve. On the T-s diagram the path leaves the liquid line and runs into the dome; no work and no heat, yet the entropy rises.
More Examples for This Tool
- Steam turbine at 85 % isentropic efficiency: work, wet exhaust and entropy generated
- Air compressor from 100 to 800 kPa: polytropic (n = 1.3) against isentropic and isothermal work
- Steam nozzle from 100 psia and 500 °F to 1 atm at 90 % efficiency
- Boiling 1 kg of water at 1 atm: 2,256.5 kJ of heat, of which 169.4 kJ pushes the atmosphere back
- Isothermal expansion of air from 500 to 100 kPa: the heat added all becomes work
- DOE handbook Mollier example: steam at 700 psia and 680 °F expanded at constant entropy to 140 psia
- DOE handbook condenser: saturated steam at 40 °C condensed and subcooled to 30 °C