Tools › Fluids and Heat Transfer › Thermodynamic Cycles › Thermodynamic Process Analyzer › Example
DOE handbook Mollier example: steam at 700 psia and 680 °F expanded at constant entropy to 140 psia
| Tool | Thermodynamic Process Analyzer |
| Source | U.S. Department of Energy (1992). DOE Fundamentals Handbook: Thermodynamics, Heat Transfer, and Fluid Flow, Volume 1 of 3. DOE-HDBK-1012/1-92, U.S. Department of Energy, Washington, DC. Module HT-01, p. 49, Example 1 (Use of Mollier Chart). |
| Level | Undergraduate |
Problem
Superheated steam at 700 psia and 680 °F is expanded at constant entropy to 140 psia. What is the change in enthalpy?
Inputs to Enter
- Water and steam, turbine with 100 % isentropic efficiency (or the closed-system isentropic process); units °F and Btu/lb
- State 1: 700 psia (4,826.3 kPa), 680 °F; exit pressure 140 psia (965.27 kPa)
Answers
- h_1 = 1,332.6 Btu/lb (handbook, read from the Mollier chart: 1,333)
- Entropy 1.5560 Btu/(lb·°R) carried to 140 psia: x_2 = (1.5560 − 0.5072)/1.068 = 0.9815, h_2 = 1,177.3 Btu/lb (handbook 1,178)
- Enthalpy change −155.3 Btu/lb (handbook −155); the steam ends slightly wet at 353.0 °F
Notes
Set the process to Turbine, the units to °F, Btu/lb and the efficiency to 100. The handbook reads a chart to the nearest Btu/lbm; the tool evaluates IAPWS-IF97.
More Examples for This Tool
- Steam turbine at 85 % isentropic efficiency: work, wet exhaust and entropy generated
- Throttling valve: saturated water at 1 MPa flashes to 15 % steam at 100 kPa
- Air compressor from 100 to 800 kPa: polytropic (n = 1.3) against isentropic and isothermal work
- Steam nozzle from 100 psia and 500 °F to 1 atm at 90 % efficiency
- Boiling 1 kg of water at 1 atm: 2,256.5 kJ of heat, of which 169.4 kJ pushes the atmosphere back
- Isothermal expansion of air from 500 to 100 kPa: the heat added all becomes work
- DOE handbook condenser: saturated steam at 40 °C condensed and subcooled to 30 °C