Tools › Civil and Geotechnical › Design Loads › Earthquake Response Spectrum


Earthquake Response Spectrum

Paste a ground acceleration record (an accelerogram) and get its elastic response spectrum: the peak displacement, pseudo-velocity and pseudo-acceleration of a damped one-story structure at every natural period, with the peak ground acceleration, velocity and displacement, the Arias intensity and the significant duration of the shaking. One oscillator is worked in full, step by step, down to its base shear. The opening record is the 1940 El Centro accelerogram from the public-domain NOAA strong-motion archive. A teaching and screening tool: it does not check a design against a building code.

  • Pasted accelerogram in g, cm/s2, m/s2, in/s2 or ft/s2, as acceleration values at a fixed time step or as time and acceleration pairs

  • Exact step-by-step solution for straight-line acceleration between samples (Nigam and Jennings), or Newmark's average acceleration method

  • Peak ground acceleration, velocity and displacement, Arias intensity, 5 to 95 % significant duration and predominant period

  • Spectral displacement, pseudo-velocity and pseudo-acceleration against period; one oscillator shown as formula, numbers, answer, with its response history and base shear

  • Optional two-parameter design spectrum drawn over the result from entered short-period and 1-second accelerations

Earthquake Response Spectrum


Unit System: /

/

1. Ground Acceleration Record






2. Structure




3. Spectrum Range and Method







4. Design Spectrum Overlay (accelerations in g)





×

Earthquake Response Spectrum

Method: the One-Story Oscillator, the Step-by-Step Solution, What It Assumes, Common Mistakes

What the tool does

It takes a recorded ground acceleration and computes how hard that shaking drives a simple one-story structure, for every natural period from stiff to flexible. The curve of peak response against period is the elastic response spectrum of the record; one structure of your choice is worked step by step.

The idea: one structure at a time

Picture a heavy roof on flexible columns. Pushed sideways and let go, it sways back and forth at its natural period T = 2π √(m / k), set by its mass m and the stiffness k of the columns, and the sway dies out at a rate set by its damping ratio ζ (5 % of critical is the usual assumption for buildings). When the ground under it shakes, the roof lags behind: the drift u is the displacement of the roof relative to the ground, and the force in the columns is k u.

A stiff structure follows the ground almost rigidly; a very flexible one stays nearly still while the ground moves under it; in between, a structure whose period matches the strong pulses of the record is driven hardest. Solve the motion for one period, keep only the largest drift, repeat for the next period, and plot the results: that plot is the response spectrum.

Left: a one-story frame with its mass displaced by a drift u relative to the shaking ground. Right: the 5 percent damped pseudo-acceleration spectrum of the 1940 El Centro record against natural period on a logarithmic axis, with a stiff structure at 0.2 s reaching 0.65 g, a medium one at 0.5 s reaching 0.82 g and a flexible one at 2 s reaching 0.18 g
The 5 % damped spectrum of the El Centro record (Imperial Valley earthquake of May 18, 1940, S00E component, peak ground acceleration 0.348 g), computed by this tool. Each point of the curve is the peak response of one structure.

Equation of motion

Dividing the force balance of the roof by its mass leaves an equation in which the mass no longer appears:

ü + 2 ζ ωn u̇ + ωn² u = − a(t),    ωn = 2π / T

Here a(t) is the ground acceleration, u̇ the velocity of the roof relative to the ground and ωn the natural circular frequency in radians per second. Two structures with the same period and damping have the same drift history whatever their size, which is why one spectrum serves every structure.

Step-by-step solution

A record is a list of accelerations a0, a1, a2, ... spaced a time step h apart. Between two samples the acceleration is taken as a straight line. For a straight-line input the equation of motion has an exact solution, so the drift and velocity at the end of a step follow from those at its start with no approximation beyond the straight line itself (Nigam and Jennings):

u1 = A u0 + B u̇0 − C a0 − D a1     u̇1 = A′ u0 + B′ u̇0 − C′ a0 − D′ a1

With ωD = ωn √(1 − ζ²), s = sin(ωD h), c = cos(ωD h), E = exp(− ζ ωn h) and r = √(1 − ζ²), the eight coefficients are:

  • A = E (ζ s / r + c)
  • B = E s / ωD
  • C = (1 / ωn²) { 2ζ / (ωn h) + E [ ((1 − 2ζ²) / (ωD h) − ζ / r) s − (1 + 2ζ / (ωn h)) c ] }
  • D = (1 / ωn²) { 1 − 2ζ / (ωn h) + E [ ((2ζ² − 1) / (ωD h)) s + (2ζ / (ωn h)) c ] }
  • A′ = − E (ωn / r) s
  • B′ = E (c − ζ s / r)
  • C′ = (1 / ωn²) { − 1 / h + E [ (ωn / r + ζ / (h r)) s + c / h ] }
  • D′ = (1 / (ωn² h)) [ 1 − E (ζ s / r + c) ]

They depend only on the period, the damping and the step, so they are computed once and the same two lines are repeated down the record, starting from rest. The tool prints the eight numbers and the first steps with the values substituted. These formulas are checked numerically against an independent solver, not against a printed table.

Sampling the peak. The peak drift is read at the ends of steps. A short-period structure can swing through its peak between two samples of the record, so the tool divides each record step into equal parts until one period holds at least 25 steps (the acceleration is still the same straight line between samples). The peak is then within 0.8 % of the true peak of the straight-line model.

After the record ends. The structure keeps swinging when the record stops. The tool follows one more period of free vibration with the ground at rest, because the largest drift of a flexible structure under a short record can come after the last sample.

Newmark's method (Advanced) replaces the exact solution by the assumption that the acceleration of the roof over a step is constant at the average of its start and end values (γ = 1/2, β = 1/4). With k̂ = ωn² + 4 ζ ωn / h + 4 / h² the same two-line recurrence holds with A = 1 − 2 ωn² / k̂, B = 4 / (h k̂), C = D = 1 / k̂, A′ = − 4 ωn² / (h k̂), B′ = 8 / (h² k̂) − 1, C′ = D′ = 2 / (h k̂). It is the general-purpose method of structural dynamics programs, since it also works for many-story and yielding structures; for this problem it is slightly less accurate than the exact recurrence (it lengthens the period by about 0.5 % at 25 steps per period).

Spectral quantities

  • Spectral displacement Sd: the largest drift |u| over the record.
  • Pseudo-velocity PSV = ωn Sd. It has the units of velocity and is related to the peak strain energy stored in the columns, ½ m PSV².
  • Pseudo-acceleration Sa = ωn² Sd. Multiplied by the mass it is exactly the peak force in the columns, k Sd. With damping it differs slightly from the peak true acceleration of the roof.
  • Seismic coefficient and base shear: Cs = Sa / g, and the peak base shear Vb = Cs W for a structure of weight W.

The three spectra are one curve read three ways; engineers plot whichever suits the period range of interest.

Ground motion measures

  • Peak ground acceleration, velocity and displacement (PGA, PGV, PGD). Velocity and displacement are the first and second integrals of the record, evaluated exactly for the straight-line acceleration, starting from the initial velocity and displacement you enter.
  • Arias intensity IA = [π / (2 g)] ∫ a² dt over the whole record, a measure of the energy the shaking delivers; it has the units of velocity.
  • Significant duration D5–95: the time between the instants at which 5 % and 95 % of the Arias intensity have arrived.
  • Predominant period: here, the period at which the computed pseudo-acceleration spectrum is largest. Other definitions exist (for example from the Fourier spectrum).

Design spectrum overlay

U.S. building codes describe the design earthquake by a smooth spectrum fixed by two accelerations, SDS at short periods and SD1 at a period of one second, and a long-period transition TL. With T0 = 0.2 SD1 / SDS and TS = SD1 / SDS (2003 NEHRP Provisions, FEMA 450, Section 3.3.4):

  • T below T0: Sa = SDS (0.4 + 0.6 T / T0)
  • T0 to TS: Sa = SDS
  • TS to TL: Sa = SD1 / T
  • above TL: Sa = SD1 TL / T²

The tool only draws this curve from the three numbers you enter. The mapped values, site coefficients and every other step of a code design belong to the code; the neighboring Wind, Snow and Seismic Loads tool works the static code loads.

The records behind "Try this"

El Centro 1940, Pacoima Dam 1971, Olympia 1949 and Golden Gate Park 1957 are corrected accelerograms from the Caltech strong-motion data set (Volume II), as distributed in the public domain on the Earthquake Strong Motion CD-ROM of NOAA's National Geophysical Data Center. Every sample of each file is used, at the file's 0.02 s step. The Golden Gate Park values are converted from cm/s² to g and rounded to five decimals. Their headers give the initial ground velocity and displacement, which the cases enter. The sine record is synthetic and illustrative.

The same data set carries the response spectra Caltech published for these records. This tool reproduces those printed values to within 1 % for periods of 0.2 s and longer at 2, 5, 10 and 20 % damping (one point of the 1,056 compared differs by 1.3 %). Below 0.2 s the published values and this tool differ by more, up to tens of percent, which is the sampling effect described next.

What it assumes

  • One degree of freedom: a single mass moving in one direction. A real building has many modes; its first mode is often treated this way.
  • Linear elastic behavior: the columns never yield or crack, and the damping is viscous and constant.
  • The ground acceleration varies as a straight line between samples, and the record is the motion at the base of the structure (no soil-structure interaction, one horizontal component).
  • The structure starts from rest and the ground is at rest after the record.

When it misleads

  • Short periods. Below about ten samples of the record per period (0.2 s for a record at 0.02 s) the result depends on how the record was sampled and filtered, not only on the earthquake. The tool flags that range.
  • Long periods. Records are filtered to remove long-period noise (the Caltech records at 0.07 Hz, about 14 s). Spectral values near and beyond the filter period are not real ground motion.
  • Displacement. The integrated ground displacement is very sensitive to the baseline and to the initial velocity. A raw record can give a displacement of meters that never happened. Even with the header's initial values the displacement integrated here differs from the one published with a corrected record, presumably because the published processing filtered the velocity and displacement again after each integration (El Centro: 12.5 cm here, 10.9 cm in the file header).
  • One record is one earthquake at one site. Its spectrum is jagged; a design spectrum is a smooth envelope over many. A record that falls below the design curve at one period says little about safety.
  • Real structures yield. Codes divide the elastic force by a response modification factor for ductility; the elastic base shear here is not a design force.

Common mistakes

  • Wrong unit for the record. A record in cm/s² read as g gives a spectrum 981 times too large; check that the peak ground acceleration in g is sensible (most strong records are between 0.05 and 1 g).
  • Wrong time step. Entering 0.02 s for a record sampled at 0.01 s stretches every period of the spectrum by two.
  • Mixing up frequency and circular frequency. ωn = 2π / T is in radians per second; the frequency in hertz is 1 / T. Using 1 / T in Sa = ωn² Sd loses a factor of 39.5.
  • Using weight where mass belongs. T = 2π √(m / k) needs the mass, W / g. The base shear is Sa times the mass, or (Sa / g) times the weight.
  • Calling the pseudo-acceleration the roof acceleration. They are equal only without damping; and neither is the peak ground acceleration.
  • Too large a step in a hand or spreadsheet solution. Read at the record's own 0.02 s samples, the peak of a 0.1 s structure can be missed by 10 % or more, and approximate methods (central difference, linear acceleration) can become unstable; keep at least 20 steps per period.
  • Comparing spectra at different damping. A 2 % spectrum sits well above a 5 % one; design spectra are for 5 %.
  • Reading time and acceleration columns as one list. The tool recognizes a time column by its steadily rising values; check the sample count it reports.

Related tools: Shock Response Spectrum (the same idea on a frequency axis for equipment shock) and SDOF Vibration (the oscillator itself).




References

National Geophysical Data Center (1996). Earthquake Strong Motion CD-ROM Collection, Volume 1. National Oceanic and Atmospheric Administration, Boulder, CO.

Hudson, D. E., and Brady, A. G. (1971). Strong-Motion Earthquake Accelerograms, Digitized and Plotted Data, Volume II: Corrected Accelerograms and Integrated Ground Velocity and Displacement Curves, Part A. Report EERL 71-50, California Institute of Technology, Pasadena, CA.

Trifunac, M. D., and Lee, V. (1973). Routine Computer Processing of Strong-Motion Accelerograms. Report EERL 73-03, California Institute of Technology, Pasadena, CA.

Nigam, N. C., and Jennings, P. C. (1969). "Calculation of Response Spectra from Strong-Motion Earthquake Records." Bulletin of the Seismological Society of America, Vol. 59, No. 2, pp. 909–922.

Newmark, N. M. (1959). "A Method of Computation for Structural Dynamics." Journal of the Engineering Mechanics Division, Vol. 85, No. 3, pp. 67–94.

Arias, A. (1970). "A Measure of Earthquake Intensity." In Hansen, R. J. (ed.), Seismic Design for Nuclear Power Plants, MIT Press, Cambridge, MA, pp. 438–483.

Trifunac, M. D., and Brady, A. G. (1975). "A Study on the Duration of Strong Earthquake Ground Motion." Bulletin of the Seismological Society of America, Vol. 65, No. 3, pp. 581–626.

Building Seismic Safety Council (2004). NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, Part 1: Provisions. FEMA 450, Federal Emergency Management Agency, Washington, DC.

Chopra, A. K. (2017). Dynamics of Structures: Theory and Applications to Earthquake Engineering, 5th ed. Pearson, Hoboken, NJ.


DISCLAIMER: The methods and calculation on aNOWysis.com are provided as means to educate the reader. There is no warranty, expessed or implied, as to the relevance or accuracy of the methods or calculations. All calculations should be checked by a qualified analyst for appropriateness and accuracy. We will not be held liable for any damages, injuries or deaths caused by using methods or calculations from this site.