Tools › Environmental › Air Quality › AP-42 Emission Estimates


AP-42 Emission Estimates

Criteria-pollutant emission estimates by the method of EPA's AP-42 Compilation of Air Emissions Factors: emissions = activity × emission factor × (1 − control efficiency ÷ 100). Built-in factor sets for natural gas, fuel oil and LPG combustion, gasoline, diesel, dual-fuel and natural gas engines and gas turbines, the AP-42 equations for unpaved roads, paved roads and aggregate drop operations, the standing and working loss of a fixed roof storage tank, and rows for entered factors. Each number carries the AP-42 table and quality rating it came from, and the facility totals are set against entered permitting thresholds. AP-42 factors are averages of a source category, and EPA does not recommend them as source-specific permit limits.

  • Sections 1.3, 1.4, 1.5 and 3.1 to 3.4 factor tables, the equations of 13.2.1, 13.2.2 and 13.2.4 and the fixed roof tank equations of 7.1, each checked against the section PDF

  • NOx, CO, SO2, PM, PM10, PM2.5, VOC and lead per source in lb/hr and tons/yr (kg/hr and tonnes/yr in SI)

  • AP-42 quality rating A to E beside every number; pollutants a section gives no factor for are listed, not guessed

  • Facility totals against the 100 and 250 tons per year definitions of the Clean Air Act, both editable

AP-42 Emission Estimates


Unit System: /

Facility and thresholds in short tons per year (the unit-system radio above only sets the units of the results: USCS gives lb/hr and tons/yr, SI gives kg/hr and tonnes/yr)




Combustion sources (built-in AP-42 factor sets; the number in brackets is the AP-42 section; a row with a blank quantity is skipped)

1
2
3

Fugitive dust sources (AP-42 equations; parameters in the units of the equations: silt content in percent, paved-road silt loading in g/m², vehicle weight in tons, speeds in mph, moisture in percent)

1
2
3

Custom factor sources (one pollutant per row; the factor in pounds per unit of the activity)

1

Fixed roof storage tank (AP-42 Section 7.1: vertical, uninsulated; lengths in feet, temperatures in °F, pressures in psi; the default is Example 1 of the section)




























Components of the stored liquid (chemical or mixture: amount in pounds or any mass proportion, molecular weight, Antoine constants A, B and C)

1
2
3
×

AP-42 Emission Estimates

AP-42 Emission Estimates

What the tool does

An emission inventory, a permit applicability screen or a fee calculation usually starts with emission factors: a published average of how much pollutant a kind of source releases per unit of what it does. The standard U.S. collection is EPA's AP-42. This tool applies a set of AP-42 factor tables and equations to the sources you list and adds the results by pollutant: nitrogen oxides (NOx), carbon monoxide (CO), sulfur dioxide (SO2), particulate matter (PM, PM10, PM2.5), volatile organic compounds (VOC) and lead. It also estimates the standing and working loss of one fixed roof storage tank. Greenhouse gases are left to the GHG Emissions Inventory tool.

One row

Every row is the general equation of the AP-42 Introduction,

E = A × EF × (1 − ER ÷ 100),

with E the emissions, A the activity rate (fuel burned, heat input, shaft work, vehicle miles, tons handled), EF the emission factor and ER the overall emission reduction efficiency in percent, which is the control device efficiency times the capture efficiency. The annual result is divided by 2,000 for short tons per year and by the operating hours for an average hourly rate. In SI the results are converted to kilograms per hour and tonnes per year (1 lb = 0.45359237 kg, 1 short ton = 907.18474 kg); the factors stay in the units AP-42 prints.

Built-in factor sets

Each factor was read in the section file published on EPA's AP-42 pages on 17 November 2026 and is shown in the results with its table and quality rating. The date in parentheses is the page date of that file.

Natural gas boilers and furnaces (Section 1.4, 10/26): NOx and CO by combustor type and control from Table 1.4-1; lead, PM, SO2 and VOC from Table 1.4-2. The factors are per 106 scf at 1,020 Btu/scf. As footnote a of the tables directs, they are multiplied by the entered heating value over 1,020, and a quantity in heat-input units uses the factor divided by 1,020. All PM is taken as smaller than 1 µm (footnote c), so PM, PM10 and PM2.5 are the same number. The SO2 factor is for 2,000 grains of sulfur per 106 scf and is scaled by the entered sulfur content.

Fuel oil (Section 1.3, 5/10): SO2 (a multiple of the sulfur weight percent S), NOx, CO and filterable PM from Table 1.3-1; condensable PM from Table 1.3-2, added to the filterable value; nonmethane total organic compounds from Table 1.3-3, reported under VOC; lead from Table 1.3-11 (No. 6 oil) or Table 1.3-10 (distillate, 9 lb per 1012 Btu). Heat contents of 140 (No. 2) and 150 (No. 6) MMBtu per 103 gal are those of Table 1.3-2.

LPG (Section 1.5, 5/25): Table 1.5-1 for butane and propane boilers, with SO2 as 0.09 S or 0.10 S, S in grains per 100 ft3 of gas. The table's total organic compounds, methane included, are reported under VOC.

Gasoline and diesel industrial engines (Section 3.3, 4/25) and large diesel and dual-fuel engines (Section 3.4, 4/25): Tables 3.3-1 and 3.4-1 print each factor twice, per horsepower-hour of output and per MMBtu of fuel input. The unit you choose for the quantity decides which is used. The organic factors are total organic compounds (for the large diesel, 91 percent of the total, the nonmethane share of its footnote f). Sulfur oxides of the large diesel are 1.01 S lb/MMBtu with S the sulfur weight percent of the fuel oil.

Natural gas-fired reciprocating engines (Section 3.2, 10/24): uncontrolled 2-stroke lean-burn, 4-stroke lean-burn and 4-stroke rich-burn engines from Tables 3.2-1, 3.2-2 and 3.2-3, per MMBtu of fuel input. NOx and CO are printed for two load ranges, 90 to 105 percent and under 90 percent, and each is a separate source type. SO2 assumes 2,000 grains of sulfur per 106 scf and is scaled by the entered value. PM, PM10 and PM2.5 are the filterable factor (taken by the tables as 1 µm or smaller) plus the condensable factor; for the 2-stroke and the rich-burn engines the condensable value is the one measured on 4-stroke lean-burn engines, as the footnotes say.

Gas turbines (Section 3.1, 4/00): NOx and CO from Table 3.1-1 for natural gas and distillate oil, uncontrolled, with water-steam injection or lean-premix; SO2, VOC, PM and lead from Table 3.1-2a, all per MMBtu of fuel input.

Sulfur inputs

The AP-42 tables state fuel sulfur in three different units, so the combustion table has three sulfur columns: weight percent (fuel oil, large diesel engines, gas turbines), grains per 100 ft3 of gas (LPG) and grains per 106 scf (natural gas boilers and engines). Each row grays the columns its factor set does not use, and only the column in the unit of the set is read: a value left behind in another column after the source type is changed is never reinterpreted.

Fixed roof storage tank

One vertical, uninsulated fixed roof tank is estimated with the routine-loss equations of Section 7.1 in its June 2026 edition (equation numbers are the section's). Total loss LT = LS + LW (1-1).

Standing loss (breathing): LS = 365 VV WV KE KS (1-2). The vapor space volume is VV = (π / 4) D² HVO (1-3) with the outage HVO = HS − HL + HRO (1-18); the roof outage HRO is one third of the roof height SR RS for a cone (1-19, 1-20), HR [1/2 + (1/6)(HR / RS)²] with HR = RR − (RR² − RS²)0.5 for a dome (1-21, 1-22), and zero for a flat roof. The vapor density is WV = MV PVA / (R TV) with R = 10.731 psia ft³ per lb-mole °R (1-24). The expansion factor is KE = ΔTV / TLA + (ΔPV − ΔPB) / (PA − PVA), kept between 0 and 1 (1-5), and the saturation factor KS = 1 / (1 + 0.053 PVA HVO) (1-23).

Temperatures. From the average daily maximum and minimum ambient temperatures, TAA is their mean (1-32) and the bulk liquid is at TB = TAA + 0.003 αS I (1-33). The liquid surface temperature TLA (1-29), the vapor temperature TV (1-34) and the daily vapor temperature range ΔTV (1-6) are the section's functions of HS / D, the roof and shell solar absorptances αR and αS (Table 7.1-6, by paint color and condition) and the daily insolation I. The vapor pressure range ΔPV is taken between TLA ± 0.25 ΔTV (Figure 7.1-17), and ΔPB is the difference of the breather vent pressure and vacuum settings (1-10).

Vapor pressure. A petroleum liquid uses PVA = exp(A − B / TLA) with T in °R (1-27); the fill offers the six stocks of Table 7.1-2 that print A and B. A chemical or a mixture uses Antoine's equation, log P = A − B / (T + C) in mm Hg and °C (1-28, with 760 mm Hg = 14.7 psia as the section states), and Raoult's law: each component contributes its pure vapor pressure times its liquid mole fraction (1-26), and the vapor molecular weight is the mole-fraction average over the vapor (1-25). The Antoine constants are entered; Table 7.1-3 of the section lists them for many chemicals.

Working loss (filling): LW = VQ KN KP WV KB (1-37), with VQ = 5.614 Q for Q barrels of net throughput per year (1-41), the turnovers N = ΣHQI / (HLX − HLN) (1-38, 1-39), KN = (180 + N) / (6 N) above 36 turnovers and 1 otherwise, KP = 0.75 for crude oil and 1 for other liquids, and KB = 1 unless the vent settings exceed ±0.03 psig and the condition of Equation 1-42 is met, when Equation 1-43 applies (with the vapor space at atmospheric pressure).

The default tank is Example 1 of the section (a benzene, toluene and cyclohexane mixture in a 6 ft tank at Denver). The section prints LS = 45.4, LW = 15.4 and LT = 60.8 lb/yr; the tool gives 45.38, 15.34 and 60.72. Every intermediate value agrees with the printed digits, and the 0.1 lb/yr difference in the working loss comes from the example rounding the vapor density to 0.0136 lb/ft³ before using it. The loss is total organic vapor and is added to the facility VOC total; the tank equations carry no letter rating in the results. The meteorological fill holds the annual values of Table 7.1-7 for Denver, Chicago and Newark only.

Fugitive dust equations

Unpaved roads (Section 13.2.2, 11/06). Industrial sites, Equation 1a: E = k (s / 12)a (W / 3)b. Public roads with light-duty traffic, Equation 1b: E = k (s / 12)a (S / 30)d / (M / 0.5)c − C. E is in pounds per vehicle mile traveled, s the surface silt content in percent, W the mean vehicle weight in tons, S the mean vehicle speed in mph, M the surface moisture content in percent, and C the exhaust, brake and tire wear of the 1980s fleet (Table 13.2.2-4). The constants k, a, b, c and d for PM2.5, PM10 and PM-30 are those of Table 13.2.2-2; PM-30 is reported as PM. With P days of at least 0.01 inch of precipitation in the year, Equation 2 multiplies the factor by (365 − P) / 365.

Paved roads (Section 13.2.1, 1/11). Equation 1: E = k (sL)0.91 (W)1.02, with sL the road surface silt loading in g/m², W the average vehicle weight in tons and k from Table 13.2.1-1 in lb per vehicle mile. Equation 2 multiplies by (1 − P / (4 N)) with N = 365 days. The factor covers resuspended road dust only: AP-42 says exhaust, brake wear and tire wear are to be added from a mobile-source model, and the tool does not add them.

Aggregate drop operations (Section 13.2.4, 11/06). Equation 1: E = k (0.0032) (U / 5)1.3 / (M / 2)1.4 pounds per ton transferred, with U the mean wind speed in mph, M the material moisture content in percent and k = 0.74, 0.35 and 0.053 for particles under 30, 10 and 2.5 µm.

Quality ratings

AP-42 rated each factor from A to E: A excellent, B above average, C average, D below average, E poor. The rating says how many tests of what quality stand behind the factor and how well they represent the source category; it is not an error band. The tool prints the letter beside every number. For the dust equations it follows the sections: the rating is lowered one letter when the precipitation correction is used, and it is withheld (a dash) when an entered parameter lies outside the range of conditions the equation was developed from. Sections 13.2.1, 13.2.2 and 13.2.4 also lower the rating when default silt or moisture values are used in place of site measurements; the tool cannot know where your values came from, so that step is yours.

Thresholds

The totals are compared with two entered thresholds in short tons per year. The defaults are the statutory definitions: a "major stationary source" emits or has the potential to emit 100 tons per year or more of any air pollutant (Clean Air Act section 302(j), 42 U.S.C. 7602(j)), and for the prevention of significant deterioration a "major emitting facility" is a listed source type at 100 tons per year or any other source at 250 tons per year (section 169(1), 42 U.S.C. 7479(1)). Lower thresholds apply in some nonattainment areas and to hazardous air pollutants, and state programs differ: enter the values of your permitting authority.

What it assumes

That each source is an average member of the category the factor was developed from, running at the conditions of the tests (the turbine factors are from units at high load, the engine factors are averages across manufacturers and duty cycles); that the entered annual activity is right; that one control efficiency applies uniformly through the year; that the hourly rate is the annual emission spread evenly over the operating hours; and that the facility hourly rate is the sum of all sources running together. Where a section gives no factor for a pollutant, the source is left out of that total and listed, never filled in with a guess.

When it misleads

AP-42 says of its own factors: "Use of these factors as source-specific permit limits and/or as emission regulation compliance determinations is NOT recommended by EPA," because about half of the sources in a category emit more than the factor. A single unit can differ from the average by a large multiple, most of all for CO and organic compounds from poorly tuned combustion and for the D and E rated factors. The comparison with a threshold describes the entered year of activity, while the statutory definitions count the potential to emit, which the permitting rules define and which is normally larger than one year's actual emissions. The hourly figure is an average, not a short-term maximum, and startup, shutdown and upset emissions are not in it. The dust equations are sensitive to silt and moisture, which change from day to day and site to site. The organic factors of the oil, LPG and engine tables are total or nonmethane organic compounds, which is not exactly the regulatory definition of VOC. Several values combine table entries in ways the tool states in the remark column (filterable plus condensable PM for oil, the condensable and lead factors of a neighboring size class). Where source tests, continuous monitors or manufacturer guarantees exist, they take precedence over any factor here.

What the tool does not do

Greenhouse gases; hazardous air pollutants and speciated organics; PM10 and PM2.5 from fuel oil (the particle-size Tables 1.3-4 to 1.3-7); coal, wood and waste fuels; controlled natural gas engines and the speciated organics of Section 3.2; sulfur oxides and PM of dual-fuel engines; landfill and digester gas turbines; floating roof tanks (external, internal and domed), horizontal, rectangular and insulated or heated fixed roof tanks, more than one tank per run, monthly tank estimates, roof landing, tank cleaning and flashing losses, and vapor pressure from Reid vapor pressure (all in Section 7.1); wind erosion of storage piles (Section 13.2.5); equipment traffic on piles other than as an unpaved road row; the hourly precipitation form of the paved road equation; and potential-to-emit calculations. A custom row takes any other factor you supply.

Checks

Every built-in factor, rating, heat content and dust constant is compared by the test script with values read by a separate program from the text of the AP-42 section files. The printed examples reproduced are the carbon monoxide example of the AP-42 Introduction (54 kg per day from 90,000 liters of distillate oil), the sulfur example of Table 1.5-1, the controlled factors of Table 13.2.2-5 and Example 1 of Section 7.1 as described above. AP-42 prints no worked example for the dust equations or the engine and turbine tables; those rows are checked against an independent calculation only.




References

U.S. Environmental Protection Agency (2024). "Introduction." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2010). "Section 1.3, Fuel Oil Combustion." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2026). "Section 1.4, Natural Gas Combustion." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2025). "Section 1.5, Liquefied Petroleum Gas Combustion." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2000). "Section 3.1, Stationary Gas Turbines." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2024). "Section 3.2, Natural Gas-fired Reciprocating Engines." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2025). "Section 3.3, Gasoline and Diesel Industrial Engines." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2025). "Section 3.4, Large Stationary Diesel and All Stationary Dual-fuel Engines." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2026). "Section 7.1, Organic Liquid Storage Tanks." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2011). "Section 13.2.1, Paved Roads." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2006). "Section 13.2.2, Unpaved Roads." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (2006). "Section 13.2.4, Aggregate Handling and Storage Piles." In AP-42: Compilation of Air Emissions Factors from Stationary Sources, 5th ed., Vol. I. Office of Air Quality Planning and Standards, Research Triangle Park, NC.

Office of the Law Revision Counsel (2023). United States Code, 2023 Edition, Title 42, Chapter 85, Air Pollution Prevention and Control, Sections 7479 and 7602. U.S. House of Representatives, Washington, DC.

Worked Examples

Published examples this tool reproduces; each page lists the inputs to enter and the printed answers.

All worked examples


DISCLAIMER: The methods and calculation on aNOWysis.com are provided as means to educate the reader. There is no warranty, expessed or implied, as to the relevance or accuracy of the methods or calculations. All calculations should be checked by a qualified analyst for appropriateness and accuracy. We will not be held liable for any damages, injuries or deaths caused by using methods or calculations from this site.