Tools › Fluids and Heat Transfer › Pipe Flow › Control Valve Sizing


Control Valve Sizing

Required flow coefficient Cv and Kv of a control valve for liquid, gas or vapour and steam service by the ISA-75.01.01 / IEC 60534-2-1 sizing equations written as mathematics: the liquid equation with the piping geometry factor FP for reducers, the choked pressure drop from the pressure recovery factor FL and the critical pressure ratio factor FF, the cavitation index, flashing and the Reynolds number factor FR for viscous flow; the gas equation with the expansion factor Y, the pressure drop ratio factor xT and the specific heat ratio factor Fk, in mass or standard-volume flow; steam with the inlet density and isentropic exponent from IAPWS-IF97, beside the simplified steam forms of the Army manual TI 810-11. For several operating cases at once the page gives the valve travel on a linear, equal-percentage or quick-opening characteristic of the entered rated Cv, the outlet velocity and Mach number against entered limits, and the installed characteristic, gain and valve authority when the pressure drop left for the valve falls with the square of the flow. Charts show Cv against travel with the operating points, flow against pressure drop with the choked limit, and the installed characteristic. The default is water at 400 gpm and 60 lb/in² drop through a 3 in valve in a 4 in line (illustrative).

  • Liquid: Cv = Q/(FP FR) sqrt(G/dP), choked at dP = (FLP/FP)2 (P1 - FF Pv), cavitation index, flashing flag, laminar and transitional flow

  • Gas, vapour and steam: W = N6 FP Cv Y sqrt(x P1 rho1) with Y = 1 - x/(3 Fk xTP), choked at x = Fk xTP; steam properties from IAPWS-IF97

  • Several operating cases: required Cv and Kv, percent travel on the chosen characteristic, outlet velocity and Mach number

  • Installed characteristic, gain and valve authority; charts of Cv against travel, flow against pressure drop and installed flow

Control Valve Sizing


Unit System: /

Service and Fluid (kinematic viscosity in cSt, dynamic viscosity in cP, molecular weight in g/mol; not converted by the unit switch)










Valve (the style fills typical FL, xT, Fd and xFz; replace them with the maker's values)













Operating Cases (inlet pressure gauge; temperature °F in USCS, °C in SI, blank for saturated steam; gas volume flow at 60 °F and 14.696 lb/in² absolute)

1
2
3

System and Limits








×

Control Valve Sizing

Control Valve Sizing: Flow Coefficient, Choked Flow, Expansion Factor and Characteristics

Scope and sources

A control valve is sized by finding the flow coefficient that passes the required flow at the available pressure drop, and then choosing a valve whose rated coefficient leaves it at a sensible travel over the whole range of operating cases. The tool uses the sizing equations of ISA-75.01.01 and IEC 60534-2-1 for incompressible and compressible fluids. Those standards are copyrighted and are cited, not reproduced: the equations are written here as mathematics, every numerical constant that is a unit conversion is computed from the definition of the flow coefficient, and the standards' tables of typical valve factors are replaced by entered inputs. The public documents that print the pieces used are the U.S. Nuclear Regulatory Commission's Cavitation Guide for Control Valves (NUREG/CR-6031: the flow coefficient and its conversions, the cavitation index, choking and the pressure recovery factor FL) and the U.S. Army Corps of Engineers Technical Instructions TI 810-11, reissued as UFC 3-410-02A (the liquid Cv and Kv equations, the simplified steam equations, and worked examples). Steam properties come from the IAPWS-IF97 formulation through the site's shared fluid-property library.

The flow coefficient

Cv is the number of US gallons per minute of water at 60 °F that pass the valve at a pressure drop of 1 lb/in², so that for any liquid Q = Cv √(ΔP/G) with Q in gpm, ΔP in lb/in² and G the relative density. In consistent units this is Q = Cv kq √(ΔP/ρ) with kq = (1 gpm) √(ρ0/(1 lb/in²)) = 2.4016 × 10−5 m7/2 kg−1/2 and ρ0 = 999.10 kg/m³, the density of water at 15 °C to which G is referred. The metric coefficient Kv is the flow in m³/h at 1 bar, Kv = 0.8650 Cv. (TI 810-11 warns that Kv is also quoted in L/s at 1 kPa, which is 1/36 of the value used here.)

All the "N" constants of the standards' equations that only carry units follow from kq: N1 = 1 (gpm, lb/in²), 0.865 (m³/h, bar), 0.0865 (m³/h, kPa); N2 = π²/(8 kq²) = 890 with the valve size in inches (0.00214 in mm), the constant of NUREG/CR-6031 equations 3.9 to 3.11, which relates Cv to the velocity-head loss coefficient, K = N2 d⁴/Cv²; N6 = 63.3 (lb/h, lb/in² absolute, lb/ft³), 27.3 (kg/h, bar, kg/m³), 2.73 (kg/h, kPa, kg/m³); N8 = 19.3 (lb/h, lb/in² absolute, °R), 94.8 (kg/h, bar, K); N9 = 7,320 (standard ft³/h at 60 °F and 14.73 lb/in², lb/in² absolute, °R), 21.2 or 22.4 (m³/h at 0 °C or 15 °C, kPa, K); N4 = 2/√(π kq/√2) = 17,300 (gpm, centistokes) or 0.0760 (m³/h, m²/s). The test script compares each computed value with the published rounded one. Two constants are the standards' own and are used as cited single facts: N5 = 1,000 (inches; 0.00241 in mm) in the fitting correction of xT, and N32 = 127 (Cv, mm) in the reduced-trim Reynolds factor.

Reducers: the piping geometry factor

A valve smaller than its line sits between a reducer and an expander. Their effect is expressed by velocity-head coefficients on the valve bore d: the inlet reducer K1 = 0.5 [1 − (d/D1)²]², the outlet expander K2 = [1 − (d/D2)²]², and the Bernoulli coefficients KB1 = 1 − (d/D1)⁴ and KB2 = 1 − (d/D2)⁴ for the change of velocity head between the pipe and the valve. With ΣK = K1 + K2 + KB1 − KB2 the valve and its fittings behave as one device of coefficient FP Cv, where FP = 1/√(1 + ΣK Cv²/(N2 d⁴)), which is simply the series addition of the loss coefficients K = N2 d⁴/Cv². Because FP contains the coefficient being sought, the tool iterates to convergence; for unchoked liquid flow the result has the closed form Cv = C0/√(1 − ΣK C0²/(N2 d⁴)) with C0 the coefficient without fittings, which the test script checks. If the reducers alone would take the whole pressure drop the tool says so. For a line-size valve every coefficient is zero and FP = 1.

Liquids: choked flow, cavitation and flashing

The liquid flow rises with √ΔP only until the pressure at the vena contracta falls to the vapour pressure. Beyond that point more pressure drop passes no more flow: the valve is choked. NUREG/CR-6031 defines the pressure recovery factor as the ratio of the choked to the unchoked coefficient (its equation 4.8), which gives the choked pressure drop of the valve alone as ΔPchoked = FL² (P1 − FF Pv). FF = 0.96 − 0.28 √(Pv/Pc) is the liquid critical pressure ratio factor, which allows for the vena-contracta pressure falling somewhat below the vapour pressure before vapour forms; the guide notes that it can be taken as 1 for water below 200 °F. With reducers the recovery factor of the combination is FLP = FL/√(1 + FL² (K1 + KB1) Cv²/(N2 d⁴)) and the choked drop is (FLP/FP)² (P1 − FF Pv). The required coefficient is Cv = Q/(N1 FP) √(G/ΔPsizing) with ΔPsizing the smaller of the actual and the choked drop.

Cavitation begins long before choking. The guide measures its intensity with the cavitation index σ = (P1 − Pv)/ΔP (its equation 2.1) and names a sequence of limits: incipient, critical, incipient damage, incipient choking and choking, the last being σch = 1/FL² when FF = 1 (equation 4.10). The tool prints σ and its reciprocal xF = ΔP/(P1 − Pv) and compares xF with two entered ratios: xFz, where cavitation begins, and optionally Kc, where the flow first departs from the square-root law (the guide's incipient choking, its equation 2.7). The default globe values rest on the measured 3 in globe valve of the guide's Figure 6.9: near 75 percent open σ is about 2.5 at incipient cavitation and 1.25 at choking, that is xFz = 0.40 and FL = 0.89. The guide stresses that the early limits change with valve size and pressure (scale effects) and must come from tests of the valve type. If the outlet pressure is at or below the vapour pressure the liquid flashes: the flow is choked and part of it leaves as vapour, which the single-phase equations do not describe beyond the choked flow rate.

TI 810-11 uses a simpler rule for hot-water valves: the maximum pressure drop without cavitation is km (pe − pv) with km = 0.45, which is the choked drop of a valve with FL = 0.67 and FF = 1. Its example (200 °F water at 20 lb/in² gauge: 10.43 lb/in²; 50 gpm at 6 lb/in²: Cv = 20.41, Kv = 17.64) is reproduced by the test script.

Viscous flow: the Reynolds number factor

The valve Reynolds number is Rev = N4 Fd Q/(ν √(Cv FL)) [FL² Cv²/(N2 D⁴) + 1]1/4. Its length scale is the hydraulic diameter of one flow passage: the vena-contracta area of the valve is Cv FL kq/√2, the diameter of a circle of that area times the valve style modifier Fd is the hydraulic diameter, and the bracket adds the velocity of approach. Above 10,000 the flow is turbulent and FR = 1. Below it the required coefficient is Cv/FR, with FR the smaller of the transitional form 1 + (0.33 √FL/n1/4) log10(Rev/10,000) and the laminar form (0.026/FL) √(n Rev), where n = N2 d⁴/Cv² for a full-size trim and n = 1 + N32 (Cv/d²)2/3 for a reduced trim (rated Cv/d² below 0.016 with d in mm). These forms and their constants are the standards'; they are stated here as recalled and were checked against the open-source implementation in the fluids library, not against a copy of the standard. The standards size non-turbulent flow without the piping geometry factor, and so does the tool. Because FR depends on the coefficient, the tool finds the smallest coefficient that satisfies Cv FR(Cv) = C0; for a full-size trim the product stops rising at large Cv, and when no coefficient satisfies the equation the tool reports that the body is too small for so viscous a flow.

Gas, vapour and steam: the expansion factor

For a compressible fluid the same coefficient is used with the inlet density and an expansion factor: W = N6 FP Cv Y √(x P1 ρ1), where x = ΔP/P1 and ρ1 = P1 M/(Z R T1) for a gas. Substituting the density gives the mass form with N8 and the standard-volume form with N9; the tool evaluates one consistent equation and converts a standard volume flow with the gas density at 60 °F and 14.696 lb/in² absolute. The expansion factor Y = 1 − x/(3 Fk xT) accounts for the fall of density through the valve. It is linear in x, equals 1 at no pressure drop and 2/3 at x = Fk xT, where the product Y √x reaches its maximum: the flow is choked and stays constant for any larger drop. xT is the pressure differential ratio factor of the valve measured with air, and Fk = k/1.4 transfers it to a gas of another specific heat ratio. With reducers xT is replaced by xTP = (xT/FP²)/(1 + xT (K1 + KB1) Cv²/(N5 d⁴)). As a consistency check, the test script compares the linear Y with the expansion factor of an ideal isentropic nozzle that chokes at the same ratio: they differ by no more than 0.051 between zero drop and choking for k from 1.2 to 1.67.

Steam is sized with the same equation. The inlet density and the isentropic exponent k = ρ w²/P (w the speed of sound) are taken from IAPWS-IF97 at the inlet pressure and temperature, dry saturated when no temperature is entered, and the outlet state for the velocity check follows from the constant-enthalpy drop. Beside it the tool prints the simplified steam equations of TI 810-11, Cv = W (1 + 0.0007 Tsh)/(2.11 √((pe + po) Δp)) below the critical drop 0.45 pe and Cv = W (1 + 0.0007 Tsh)/(1.74 pe) at or above it (lb/h, lb/in² absolute, °F of superheat). They contain no valve-specific factor, so they agree with the equation above only for a valve whose Fk xT is near 0.45; the manual's examples (250 lb/h from 5 to 2 lb/in² gauge: Cv = 11.34; 6,000 lb/h at the critical drop with 48 °F of superheat: Kv = 77.5) are reproduced by the test script. Two details of the second example differ: the inch-pound value printed, 89.1, corresponds to an inlet pressure rounded to 40 lb/in² absolute (39.7 gives 89.8), and IAPWS-IF97 gives 45.7 °F of superheat for the throttling from 125 to 25 lb/in² gauge.

Characteristic, travel, installed characteristic and authority

The inherent characteristic is the fraction f of the rated coefficient at the travel fraction h under constant pressure drop: linear f = h; equal percentage f = Rh − 1, in which equal steps of travel multiply the coefficient by equal ratios and R is the rangeability; quick opening, idealised here as f = √h. The travel of each operating case is the inverse of that function at f = Cv/Cv,rated.

In a system the pressure drop across the valve is not constant. The pump or supply and the rest of the circuit leave the valve a drop that falls roughly with the square of the flow, ΔP(F) = ΔP0 − (ΔP0 − ΔPd)(F/Fd)², from the entered no-flow value to the drop of the design case. The installed characteristic is the flow at each travel for which the valve equation and this curve agree, found numerically for every fluid. For an unchoked liquid valve without reducers it has the closed form q = f/√(N + (1 − N) f²), where q is the flow as a fraction of the fully open flow and N, the valve authority, is the pressure drop of the fully open valve divided by the no-flow drop. A low authority bends an equal-percentage characteristic toward linear and a linear one toward quick opening. The installed gain dq/dh is tabulated; a loop tuned at one operating point keeps its margin where the gain changes little. TI 810-11 requires the valve to take at least half of the circuit pressure drop at full flow.

Velocity checks and what is left out

The outlet velocity is the volume flow at the outlet state through the valve bore; for gas and steam the Mach number refers to the speed of sound at that state. Both are compared with entered limits, since the acceptable values depend on the valve design and the service. Noise prediction (IEC 60534-8-3 for gases, 8-4 for liquids) and two-phase sizing are outside the tool. The factors FL, xT, Fd and xFz filled by the style list are typical values for a first estimate: only the globe FL and xFz are tied to a public measurement (NUREG/CR-6031 Figure 6.9); the others are recalled typical values and unverified. The final sizing uses the certified factors of the selected valve at the travel in question.

Worked examples reproduced

NUREG/CR-6031: the 24 in butterfly valve of section 3.2 (21,000 gpm at 0.355 lb/in² gross and 0.227 net: Cv = 35,200 and 44,100); Example 6.1 (σ = 2.13); Example 6.4 (6 in butterfly valve, Cd = 0.60: Cv = 805; σ = 1.77 against σch = 2.9: choking, ΔPch = 30.54 lb/in²). The guide's last line of that example prints Q = 805/(30.54)0.5 = 145 gpm; the coefficient equation gives Q = 805 √30.54 = 4,449 gpm, which is what the tool returns. TI 810-11: the examples named above. The default case of the tool (water, 400 gpm at 60 lb/in², 3 in valve in a 4 in line, rated Cv 120) is illustrative and has no printed source: Cv = 51.93, Kv = 44.91, travel 78.6 percent.




References

Tullis, J. P. (1993). Cavitation Guide for Control Valves. NUREG/CR-6031, U.S. Nuclear Regulatory Commission, Washington, DC.

U.S. Army Corps of Engineers (1998). Heating, Ventilating and Air Conditioning (HVAC) Control Systems. Technical Instructions TI 810-11, 30 November 1998, Washington, DC.

U.S. Department of Defense (2003). Heating, Ventilating and Air Conditioning (HVAC) Control Systems. UFC 3-410-02A, 15 May 2003.

International Society of Automation (2012). Industrial-Process Control Valves, Part 2-1: Flow Capacity, Sizing Equations for Fluid Flow Under Installed Conditions. ANSI/ISA-75.01.01-2012 (IEC 60534-2-1 Mod), Research Triangle Park, NC.

International Electrotechnical Commission (2011). Industrial-Process Control Valves, Part 2-1: Flow Capacity, Sizing Equations for Fluid Flow Under Installed Conditions. IEC 60534-2-1, 2nd ed., Geneva.

International Electrotechnical Commission (2010). Industrial-Process Control Valves, Part 8-3: Noise Considerations, Control Valve Aerodynamic Noise Prediction Method. IEC 60534-8-3, 3rd ed., Geneva.

International Society of Automation (1995). Considerations for Evaluating Control Valve Cavitation. ISA-RP75.23-1995, Research Triangle Park, NC.

Driskell, L. (1983). Control-Valve Selection and Sizing. Instrument Society of America, Research Triangle Park, NC.

Bell, C. (2016–2025). fluids: Fluid Dynamics Component of Chemical Engineering Design Library. Open-source software, MIT licence.

International Association for the Properties of Water and Steam (2007). Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam. IAPWS R7-97(2012), Lucerne.

Worked Examples

Published examples this tool reproduces; each page lists the inputs to enter and the printed answers.

All worked examples


DISCLAIMER: The methods and calculation on aNOWysis.com are provided as means to educate the reader. There is no warranty, expessed or implied, as to the relevance or accuracy of the methods or calculations. All calculations should be checked by a qualified analyst for appropriateness and accuracy. We will not be held liable for any damages, injuries or deaths caused by using methods or calculations from this site.