Tools › Environmental › Air Quality › Air Dispersion Screening


Air Dispersion Screening

Screening estimate of the ground-level concentration downwind of a stack, a flare or a volume source by the steady-state Gaussian plume of EPA's SCREEN3 procedure: Pasquill-Gifford rural and Briggs urban dispersion coefficients for stability classes A to F, Briggs buoyant and momentum plume rise, stack-tip downwash, buoyancy-induced dispersion, ground and mixing-lid reflections and the wind-speed profile to stack height. The tool scans every stability class and wind speed of the screening matrix for the worst case, finds the maximum one-hour concentration and its distance, converts it to longer averaging times with the EPA screening factors, expresses it in micrograms per cubic metre and ppm, and compares it with an ambient air-quality standard. It is a screening estimate, not a regulatory model run.

  • Maximum 1-hour concentration and its distance over all stability classes and wind speeds, as SCREEN3 does

  • Briggs plume rise, stack-tip downwash, effective height, buoyancy-induced dispersion, mixing-lid reflections

  • Concentration against distance for each class, crosswind profile, receptor grid, flagpole receptors, simple elevated terrain

  • EPA averaging-time factors (3, 8, 24 hours, annual), ppm from the molecular weight, comparison with a NAAQS or an entered standard

Air Dispersion Screening


Unit System: /

Source (temperatures in kelvin in both unit systems)














Site and Receptors







Meteorology





Pollutant, Averaging Time and Standard (concentrations in µg/m³ in both unit systems)







×

Air Dispersion Screening

Method, Equations and Sources

What the tool does

An air-permit application for a stack usually starts with a screening calculation: the highest ground-level concentration the source could cause under the worst weather, compared with an ambient air-quality standard. If the screening result is comfortably below the standard, no more modelling is normally asked for; if it is not, a refined model is run with real meteorology. This tool makes the screening estimate the way EPA's SCREEN3 program does for a single source in simple terrain: a steady-state Gaussian plume, Pasquill stability classes A to F, Briggs plume rise, and a search over every stability class and wind speed for the worst case. It reproduces SCREEN3's printed examples for a flare and a volume source to every digit (see the worked example). It is not SCREEN3 itself and it is not a regulatory model run: building downwash, complex terrain, fumigation and area sources, which SCREEN3 also covers, are left out and named in the results.

The plume equation

The 1-hour concentration at a receptor x downwind, y off the plume centreline and zr above the ground is (ISC3 User's Guide Volume II, eq. 1-1)

C = Q V exp(−y² / (2 σy²)) / (2π us σy σz),

with Q the emission rate, us the wind speed at release height and σy, σz the lateral and vertical dispersion coefficients at x. With Q in g/s and the factor 106 the result is in µg/m³. The vertical term V holds the Gaussian exp(−(zr − H)² / (2 σz²)), its image in the ground exp(−(zr + H)² / (2 σz²)) and, for the unstable and neutral classes, the images in the mixing lid at heights 2 i zi ± H (i = 1, 2, …). When σz / zi reaches 1.6 the plume is uniformly mixed below the lid and V = √(2π) σz / zi. The stable classes E and F have no lid. H is the plume height: release height (after stack-tip downwash) plus the final plume rise, less the terrain height when simple elevated terrain is entered.

Dispersion coefficients

Rural: the Pasquill-Gifford curves in the equation form of the ISC3 guide. σy = 465.11628 x tan(θ) with θ = 0.017453293 (c − d ln x), x in km, and c, d by class (Table 1-1); σz = a xb with a and b given by class and distance range (Table 1-2). Urban: the Briggs fits to the McElroy-Pooler data (Tables 1-3 and 1-4), for example σy = 0.16 x (1 + 0.0004 x)−1/2 and σz = 0.14 x (1 + 0.0003 x)−1/2 for class D with x in metres. σz is not allowed above 5,000 m. For class A the tool uses c = 24.1667 as the SCREEN3 program does; the ISC3 table prints 24.1670, a difference of two parts in a million in σy.

A buoyant plume spreads as it rises. Following Pasquill, the coefficients are enlarged by the buoyancy-induced term σ = Δh(x) / 3.5 added in quadrature, σy = (σy² + σ²)1/2 and the same for σz, where Δh(x) is the transitional rise at the receptor distance (ISC3 Section 1.1.5.2).

Wind speed at release height

The screening wind speeds are 10 m values. The speed at release height is us = uref (hs / zref)p, never below 1 m/s, with the exponent p = 0.07, 0.07, 0.10, 0.15, 0.35, 0.55 for classes A to F in rural settings and 0.15, 0.15, 0.20, 0.25, 0.30, 0.30 in urban settings (ISC3 Section 1.1.3). For a release below 10 m the 10 m speed is used unchanged.

Plume rise (Briggs)

The buoyancy flux is Fb = g vs ds² (Ts − Ta) / (4 Ts) and the momentum flux Fm = vs² ds² Ta / (4 Ts) (ISC3 eqs. 1-8, 1-9). Whether buoyancy or momentum governs is decided by comparing Ts − Ta with a crossover temperature difference (eqs. 1-10, 1-11 and 1-18).

  • Unstable and neutral, buoyant: Δh = 21.425 Fb3/4 / us for Fb below 55 m4/s3, else 38.71 Fb3/5 / us; final rise is reached at xf = 49 Fb5/8 or 119 Fb2/5.
  • Unstable and neutral, momentum: Δh = 3 ds vs / us.
  • Stable, buoyant: Δh = 2.6 (Fb / (us s))1/3 with the stability parameter s = g (∂θ/∂z) / Ta and ∂θ/∂z = 0.020 K/m for class E, 0.035 K/m for class F; xf = 2.0715 us / √s. The program also applies the calm-wind limit 4 Fb1/4 / s3/8 when it is lower.
  • Stable, momentum: Δh = 1.5 (Fm / (us √s))1/3, not above the neutral momentum rise.
  • Transitional rise before xf: Δh(x) = 1.60 Fb1/3 x2/3 / us for buoyant plumes (eq. 1-22) and the jet relations of eqs. 1-23 and 1-25 for momentum plumes, never above the final rise.
  • Stack-tip downwash: when vs is less than 1.5 us the release height becomes hs′ = hs + 2 ds (vs / us − 1.5) (eq. 1-7).

Like SCREEN3, the tool places the plume at its final height at every distance when no building wake is involved, and uses the transitional rise only in the buoyancy-induced spread. Two details follow the SCREEN3 program where it differs from the printed ISC3 text: the stable crossover temperature difference is evaluated with the ambient temperature (the text of eq. 1-18 prints Ts), and g = 9.80616 m/s².

Worst-case meteorology and mixing height

Full meteorology examines the wind speeds 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 8, 10, 15 and 20 m/s at 10 m with the classes they can occur with: A up to 3 m/s, B up to 5, C up to 10, D up to 20, E up to 5 and F up to 4 m/s (SCREEN3 User's Guide, Table 2). The mechanical mixing height for the unstable and neutral classes is zi = 320 u10 (guide eq. 4), raised to H + 1 m when the plume would otherwise be above it, so that the plume is always kept below the lid, which is the conservative choice. Beyond 50 km speeds below 2 m/s are raised to 2 m/s. The maximum is found by scanning the envelope of all conditions between the entered distances and refining it to the nearest metre.

Flare and volume source

Flare (guide Sections 2.5 and 3.3): with H the total heat release in cal/s, 55 % is assumed radiated; the effective release height is the flare height plus 4.56×10−3 H0.478 m (the flame is taken as tilted 45°), the gas is given an exit velocity of 20 m/s and a temperature of 1,273 K in air at 293 K, and the effective diameter 9.88×10−4 (0.45 H)0.5 m then reproduces the guide's buoyancy flux Fb = 1.66×10−5 H (its eq. 6). The tool takes the heat release in watts and converts with 4.1868 J/cal.

Volume source (guide Section 2.7): no plume rise; the initial dimensions σy0 and σz0 are honoured by adding virtual distances xy and xz, found by inverting the coefficient formulas, to the receptor distance. Receptors closer than 2.15 σy0 are inside the source and get no value. The guide's rules for the initial dimensions: side length divided by 4.3 for σy0; vertical dimension divided by 2.15 for a surface-based source, building height divided by 2.15 for a source on or next to a building, and vertical dimension divided by 4.3 for an elevated source.

Longer averaging times

EPA's screening procedures (EPA-454/R-92-019, Section 4.2, Step 5) estimate the maximum for longer averaging times by multiplying the 1-hour maximum by 0.9 (± 0.1) for 3 hours, 0.7 (± 0.2) for 8 hours, 0.4 (± 0.2) for 24 hours and 0.08 (± 0.02) for the annual average. The values in parentheses are the limits within which the factor may be changed for a particular source with the agreement of the reviewing agency (toward the high side for low releases and downwash or terrain problems). The tool applies the general-case factor, lets it be edited and warns when it is outside the limits.

ppm and the standard

For a gas, ppm by volume = C [µg/m³] × Vm / (1,000 M), with M the molecular weight in g/mol and Vm = R T / P = 24.465 L/mol at the reference conditions of 40 CFR 50.3 (25 °C, 760 mm Hg). The preset standards are the levels of 40 CFR Part 50 as in force on 1 October 2025: sulfur dioxide 75 ppb (1 hour) and 0.5 ppm (3 hours, secondary), nitrogen dioxide 100 ppb (1 hour) and 53 ppb (annual), carbon monoxide 35 ppm (1 hour) and 9 ppm (8 hours), PM10 150 µg/m³ (24 hours), PM2.5 35 µg/m³ (24 hours) and 9.0 µg/m³ (annual). They are cited values in editable fields: check the current rule, the form of the standard and any state or local limit. Because the concentration is proportional to the emission rate, the tool also reports the emission rate at which the screening total, with the entered background, would just equal the standard.

Limits

  • Building downwash is not modelled. EPA's rule of thumb (screening procedures eq. 4.11) is that a stack at least hb + 1.5 Lb tall, with hb the height of a building within five times Lb and Lb the lesser of its height and projected width, is unlikely to be affected; a shorter stack needs the downwash and cavity calculations of SCREEN3 or a refined model.
  • Simple terrain only: receptors at or below the release height. The terrain height entered lowers the plume height for every receptor.
  • No inversion break-up or shoreline fumigation, no area sources, no deposition or settling, no chemistry.
  • One source at a time; add the background and other nearby sources before a comparison.
  • The current preferred screening model under 40 CFR 51 Appendix W is AERSCREEN, the screening version of AERMOD (Section 4.2.1.1 of the Guideline), which also handles building downwash and complex terrain. Ask the reviewing agency which screening method it expects before relying on a SCREEN3-type estimate.

Checks

The library reproduces every printed line of the flare example (pages 29 to 31) and the volume-source example (page 40) of the SCREEN3 User's Guide, and the buoyancy and momentum fluxes of its point-source example (page 22); an independent numpy and scipy implementation written from the ISC3 text agrees on twenty random stacks; the crosswind-integrated mass flux equals the emission rate.




References

U.S. Environmental Protection Agency (1995). SCREEN3 Model User's Guide. EPA-454/B-95-004, Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (1995). User's Guide for the Industrial Source Complex (ISC3) Dispersion Models, Volume II: Description of Model Algorithms. EPA-454/B-95-003b, Office of Air Quality Planning and Standards, Research Triangle Park, NC.

U.S. Environmental Protection Agency (1992). Screening Procedures for Estimating the Air Quality Impact of Stationary Sources, Revised. EPA-454/R-92-019, Office of Air Quality Planning and Standards, Research Triangle Park, NC.

Turner, D. B. (1970). Workbook of Atmospheric Dispersion Estimates, revised ed. Office of Air Programs Publication No. AP-26, U.S. Environmental Protection Agency, Research Triangle Park, NC.

Briggs, G. A. (1969). Plume Rise. TID-25075, U.S. Atomic Energy Commission, Division of Technical Information, Oak Ridge, TN.

Briggs, G. A. (1975). "Plume Rise Predictions." In Haugen, D. A. (ed.), Lectures on Air Pollution and Environmental Impact Analyses, American Meteorological Society, Boston, pp. 59–111.

U.S. Environmental Protection Agency (2024). Guideline on Air Quality Models. Code of Federal Regulations, Title 40, Part 51, Appendix W.

U.S. Environmental Protection Agency (2025). National Primary and Secondary Ambient Air Quality Standards. Code of Federal Regulations, Title 40, Part 50.

Worked Examples

Published examples this tool reproduces; each page lists the inputs to enter and the printed answers.

All worked examples


DISCLAIMER: The methods and calculation on aNOWysis.com are provided as means to educate the reader. There is no warranty, expessed or implied, as to the relevance or accuracy of the methods or calculations. All calculations should be checked by a qualified analyst for appropriateness and accuracy. We will not be held liable for any damages, injuries or deaths caused by using methods or calculations from this site.