Tools › Fluids and Heat Transfer › Thermodynamic Cycles › Combustion and Flue Gas


Combustion and Flue Gas

Fuel and air combustion calculations for boiler, furnace and heater work. The fuel is a gas entered by mole percent (methane, ethane, propane, butane, carbon dioxide, nitrogen, hydrogen, carbon monoxide, hydrogen sulfide) or a liquid or solid entered by ultimate analysis, with cited example fuels. Results: higher and lower heating value, stoichiometric and actual air by mass and volume, excess air from an entered value or from the measured dry-basis oxygen or carbon dioxide, flue-gas composition wet and dry, flue-gas mass and volume per unit of fuel, water dew point, adiabatic flame temperature from NASA Glenn enthalpy fits without dissociation, stack losses and combustion efficiency by the heat-loss method, the F factors of EPA Method 19 computed from the composition beside the regulation's table, and the conversion of a concentration in ppm at a reference oxygen to pounds per million Btu. Default: pipeline natural gas with 3 % oxygen in the dry flue gas and a 400 °F stack.

  • Gas by mole percent or liquid and solid fuel by ultimate analysis; example fuels from NETL, Army TM 5-650 and the USDA Forest Service

  • Stoichiometric air, excess air from measured O2 or CO2, flue-gas composition, mass, volume and water dew point

  • Heating values from NASA enthalpies of formation; adiabatic flame temperature without dissociation; stack losses and combustion efficiency

  • EPA Method 19 F factors from the composition and ppm at a reference O2 converted to lb per million Btu

Combustion and Flue Gas


Unit System: /

Fuel


Gas composition, mole percent










Ultimate analysis, percent by mass as fired, and higher heating value










Air and flue gas (temperatures in °F in USCS and °C in SI; the unit switch does not convert them)











Emission rate conversion, EPA Method 19






×

Combustion and Flue Gas

Combustion and Flue Gas

What the tool does

Burner tuning, stack sizing, emission reporting and heat-recovery studies all start from the same bookkeeping: how much air a fuel needs, what the flue gas is made of, how much of it there is, and how much of the fuel's heat it carries away. This tool does that bookkeeping for a gas entered by mole percent or a liquid or solid fuel entered by ultimate analysis. It reports heating values, stoichiometric and actual air, excess air from a measured oxygen or carbon dioxide reading, the wet and dry flue-gas composition, the mass and volume of flue gas per unit of fuel, the water dew point, an adiabatic flame temperature, the stack losses with the combustion efficiency, and the F factors of EPA Method 19 with the conversion of a concentration in ppm to pounds per million Btu.

The boiler efficiency with casing, unburned-carbon and blowdown losses and the steam-side balance are a different job: use Steam System and Boiler Efficiency. Emission estimates from published factors are in AP-42 Emission Estimates.

Fuel

A gaseous fuel is a mixture of methane, ethane, propane, n-butane, carbon dioxide, nitrogen, hydrogen, carbon monoxide and hydrogen sulfide in mole (volume) percent, normalized to 100 %. Its higher heating value is the mole-fraction sum of the heats of combustion of the components at 25 °C, each computed from the enthalpies of formation in NASA/TP-2002-211556 with liquid water as the product (methane 890.57, ethane 1,560.7, propane 2,219.2, n-butane 2,877.4, hydrogen 285.83, carbon monoxide 282.97, hydrogen sulfide 562.0 kJ/mol). The volume basis treats the gas as ideal at the chosen standard temperature and 101.325 kPa; a real-gas compressibility correction, about 0.2 % for natural gas, is not applied.

A liquid or solid fuel is an ultimate analysis in percent by mass as fired (carbon, hydrogen, oxygen, nitrogen, sulfur, ash, moisture) with an entered higher heating value. If the heating value is left blank the tool uses the Dulong formula, HHV = 14,544 C + 62,028 (H − O ÷ 8) + 4,050 S Btu/lb with mass fractions, and says so. The Dulong coefficients are typed from memory, not read in a public document for this tool; the formula is an approximation within a few percent for coals and oils and about 8 % low for the example wood.

The lower heating value is the higher one less the latent heat of the water formed from the hydrogen and of the fuel moisture, 44.004 kJ/mol at 25 °C.

The example fuels are: natural gas, the mean of over 6,800 pipeline samples in NETL's feedstock specification (Exhibit 1-1); No. 2 and No. 6 fuel oil from the footnotes of Tables 1-5 and 1-6 of Army TM 5-650; Illinois No. 6 bituminous coal as received from the NETL specification (Exhibit 1-2, its 0.29 % chlorine counted with the ash); oven-dry wood as the approximate composition and 8,500 Btu/lb of USDA Forest Service report FPL 29, and the same wood at 45 % moisture by arithmetic. Propane and n-butane are the pure compounds. They are examples: use the analysis of your own fuel.

Air and flue gas

Per unit mass of fuel, with the moles of carbon, hydrogen, sulfur and oxygen atoms it contains, the oxygen for complete combustion is

O2 = C + H ÷ 4 + S − O ÷ 2.

Dry air is taken as 20.9476 % oxygen, 0.934 % argon, 0.0314 % carbon dioxide and the balance nitrogen by volume (U.S. Standard Atmosphere, 1976), so the stoichiometric air is that oxygen divided by 0.209476. The actual air is the stoichiometric air times (1 + excess air). Carbon leaves as CO2, hydrogen as H2O, sulfur as SO2, fuel nitrogen as N2; the unused oxygen, the nitrogen and argon of the air, the fuel moisture and the moisture of the air pass through. An entered carbon monoxide reading (ppm, dry) moves that much carbon from CO2 to CO and frees half a mole of oxygen per mole.

When the excess air is not entered, the tool finds the excess air at which this balance returns the measured dry-basis oxygen or carbon dioxide. An oxygen reading is the more robust of the two: it depends little on the fuel, while the carbon dioxide reading depends strongly on the carbon-to-hydrogen ratio.

Standard volumes are ideal-gas volumes at 101.325 kPa and the temperature you choose (60 °F, 68 °F, 15 °C or 0 °C); the actual stack volume uses the stack temperature and the barometric pressure. The water dew point is the saturation temperature (IAPWS-IF97) at the partial pressure of water vapor in the wet flue gas.

Adiabatic flame temperature

The products of complete combustion take up the lower heating value plus the sensible enthalpy that the air (and a gaseous fuel) bring above 25 °C. The temperature at which the enthalpy of the products, from the NASA Glenn nine-coefficient fits of each constituent, equals that sum is the adiabatic flame temperature at constant pressure. Methane in dry air at 25 °C with no excess air gives 2,326 K, hydrogen 2,520 K.

No dissociation is modeled. Above about 1,800 K carbon dioxide and water vapor dissociate and the equilibrium temperature is lower, by roughly 100 K for hydrocarbons in air near the stoichiometric ratio and by much more in oxygen-enriched air. Treat the result as an upper bound and as a way to compare cases, not as a furnace temperature.

Stack losses and combustion efficiency

The heat-loss method on the higher heating value, with fuel and air entering at the air temperature Ta and the flue gas leaving at the stack temperature Ts:

dry gas loss = Σ ni [hi(Ts) − hi(Ta)] over the dry constituents;

water from hydrogen and fuel moisture = nw {44.004 kJ/mol + [hv(Ts) − hv(25 °C)] − [hl(Ta) − hl(25 °C)]}, because the higher heating value counts that water as condensed;

air moisture = nw,air [hv(Ts) − hv(Ta)]; carbon monoxide = nCO × 282.97 kJ/mol.

Combustion efficiency = 100 % − the sum of these as a percentage of the higher heating value; the same heat divided by the lower heating value is also shown. This is the same loss accounting as in the Steam System and Boiler Efficiency tool, limited here to the flue gas and extended to gas mixtures; that tool adds radiation, unburned carbon, unaccounted losses and the steam side. ASME PTC 4 is the governing test code for a boiler efficiency test and is cited only.

EPA Method 19 F factors

Method 19 (40 CFR Part 60, Appendix A-7) converts a measured concentration to an emission rate per unit of heat input with an F factor, "the ratio of the gas volume of the products of combustion to the heat content of the fuel" at 20 °C and 760 mm Hg: Fd dry, Fw wet, Fc carbon dioxide. The tool prints three sets side by side: the element balance of the entered fuel with air of 20.9 % oxygen (the method's convention), the method's Equations 19-13 to 19-15 applied to the ultimate analysis, and the average factor of Table 19-2 for the fuel class. The equations are

Fd = 106 (3.64 %H + 1.53 %C + 0.57 %S + 0.14 %N − 0.46 %O) ÷ GCV, Fw = 106 (5.57 %H + 1.53 %C + 0.57 %S + 0.14 %N − 0.46 %O + 0.21 %H2O) ÷ GCV, Fc = 106 (0.321 %C) ÷ GCV,

in scf per million Btu with the gross calorific value GCV in Btu/lb. The emission rate is Equation 19-1, E = Cd Fd × 20.9 ÷ (20.9 − %O2d), with the dry concentration Cd in lb/scf: ppm × 1.194 × 10−7 for NOx (as NO2) and ppm × 1.660 × 10−7 for SO2 (Table 19-1); for CO or an entered molar mass the factor is the molar mass divided by the ideal-gas molar volume at 20 °C. The regulation text was read in the eCFR as of 13 November 2026.

The element balance reproduces the printed constants of the equations within 0.7 % (hydrogen is the largest difference), and the computed Fd and Fw of the example fuels are within 2.6 % of Table 19-2. The table's propane and butane rows carry the same Fd as natural gas, while the pure compounds give 1.7 % and 2.3 % more. The table has a single oil row: the example No. 2 oil is within 0.5 % of it, while the example No. 6 oil gives an Fd 2.5 % and an Fc 9 % above it. The example wood gives an Fc 3 % above the table.

What it assumes

Complete combustion with at least the stoichiometric air; no soot, unburned hydrocarbons or unburned carbon in ash; no dissociation and no nitrogen oxide formation in the balance; ideal gases; sulfur to SO2 only; all water leaving as vapor; fuel and air entering at one temperature; heating values at 25 °C used at that temperature; the sensible heat of a preheated liquid or solid fuel left out.

When it misleads

Below the stoichiometric air or with heavy smoke the balance does not hold. With the stack below the water dew point (condensing boilers) part of the latent heat is recovered and the efficiency shown is too low. A fuel analysis that is not the fuel actually fired moves every result: the carbon dioxide route to excess air is especially sensitive. Air leaking into the flue between the furnace and the analyzer reads as excess air. Fuels with sulfur have an acid dew point well above the water dew point, which is not estimated here. The flame temperature is an upper bound, as explained above. F factors from one analysis are not automatically the ones a permit requires.

Verification

The library is checked against the regulation text and table of Method 19, the printed heating values of NETL's natural gas (the tool is 0.55 % lower by mass and 0.5 % lower by volume), the oxygen and excess-air pairs and the efficiency table of DOE Steam Tip Sheet #4 (the tool reads 0.4 to 0.8 point above the sheet with the example natural gas; the sheet does not state its fuel analysis or method), the stoichiometric oxygen and air of USDA report FPL 29, the methane example and the water saturation table of EPA's APTI Course 427 manual, NIST saturation data for the dew point, and an independent numerical model (element balances by linear solve, enthalpies by quadrature of the heat-capacity fits, root finding for excess air and flame temperature) on the example fuels and sixty random fuels.




References

U.S. Environmental Protection Agency (2026). "Method 19: Determination of Sulfur Dioxide Removal Efficiency and Particulate Matter, Sulfur Dioxide, and Nitrogen Oxide Emission Rates." In Code of Federal Regulations, Title 40, Part 60, Appendix A-7, Office of the Federal Register, Washington, DC.

McBride, B. J., Zehe, M. J., and Gordon, S. (2002). NASA Glenn Coefficients for Calculating Thermodynamic Properties of Individual Species. NASA/TP-2002-211556, NASA Glenn Research Center, Cleveland, OH.

National Energy Technology Laboratory (2012). Quality Guidelines for Energy System Studies: Specification for Selected Feedstocks. DOE/NETL-341/011812, U.S. Department of Energy, Pittsburgh, PA.

Department of the Army (1989). Central Boiler Plants. Technical Manual TM 5-650, Headquarters, Department of the Army, Washington, DC.

Ince, P. J. (1979). How to Estimate Recoverable Heat Energy in Wood or Bark Fuels. General Technical Report FPL 29, U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI.

U.S. Department of Energy, Advanced Manufacturing Office (2012). Energy Tips: Steam. Steam Tip Sheet #4, Improve Your Boiler's Combustion Efficiency. DOE/GO-102012-3405, U.S. Department of Energy, Washington, DC.

Doyle, B. W. (2015). Combustion Source Evaluation: Student Manual, APTI Course 427, 3rd ed. U.S. Environmental Protection Agency, Air Pollution Training Institute, Research Triangle Park, NC.

International Association for the Properties of Water and Steam (2012). Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam. IAPWS R7-97(2012), IAPWS, Lucerne.

National Oceanic and Atmospheric Administration, National Aeronautics and Space Administration, and United States Air Force (1976). U.S. Standard Atmosphere, 1976. NOAA-S/T 76-1562, U.S. Government Printing Office, Washington, DC.

American Society of Mechanical Engineers (2013). Fired Steam Generators: Performance Test Codes. ASME PTC 4-2013, ASME, New York.

Worked Examples

Published examples this tool reproduces; each page lists the inputs to enter and the printed answers.

All worked examples


DISCLAIMER: The methods and calculation on aNOWysis.com are provided as means to educate the reader. There is no warranty, expessed or implied, as to the relevance or accuracy of the methods or calculations. All calculations should be checked by a qualified analyst for appropriateness and accuracy. We will not be held liable for any damages, injuries or deaths caused by using methods or calculations from this site.