Tools › Fluids and Heat Transfer › Thermodynamic Cycles › Combustion and Flue Gas › Example

Pipeline natural gas at 3 % flue-gas oxygen: heating value, excess air, flue gas, stack loss and the EPA Method 19 F factors

ToolCombustion and Flue Gas
SourceNational Energy Technology Laboratory (2012). Quality Guidelines for Energy System Studies: Specification for Selected Feedstocks. DOE/NETL-341/011812, U.S. Department of Energy, Pittsburgh, PA. Exhibit 1-1 (natural gas composition and heating values); U.S. Environmental Protection Agency, Method 19, 40 CFR Part 60, Appendix A-7, Equations 19-1 and 19-13 to 19-15, Tables 19-1 and 19-2; U.S. Department of Energy, Steam Tip Sheet #4, DOE/GO-102012-3405 (excess air against flue-gas oxygen).
LevelUndergraduate

Problem

A burner fires the mean U.S. pipeline natural gas of NETL's feedstock specification (methane 93.1, ethane 3.2, propane 0.7, n-butane 0.4, carbon dioxide 1.0, nitrogen 1.6 % by volume). The analyzer reads 3 % oxygen in the dry flue gas, the stack is at 400 °F and the air at 77 °F. Find the heating value, the excess air, the flue-gas composition and dew point, the stack loss, the Method 19 F factors of the gas, and the emission rate of 30 ppm NOx at 3 % oxygen in pounds per million Btu.

Inputs to Enter

  • Fuel: Natural gas (the default); composition 93.1 / 3.2 / 0.7 / 0.4 / 1.0 / 1.6 mole percent
  • Excess air from measured O2, dry: 3 %; CO 0 ppm; air 77 °F, dry; stack 400 °F; 14.696 psi; standard volumes at 60 °F
  • Table 19-2 fuel: Gas, natural; pollutant NOx as NO2, 30 ppm at 3 % reference oxygen
Open the Combustion and Flue Gas tool (loaded with this example)

Answers

  • Higher heating value 22,482 Btu/lb and 1,027 Btu/scf (book 22,600 Btu/lb and 1,032 Btu/scf: the tool is 0.5 % lower with NASA enthalpies of formation); lower heating value 20,292 Btu/lb (book 20,410)
  • Stoichiometric air 16.24 lb/lb = 9.715 scf/scf; excess air 15.03 % (the tip sheet prints 15.0 % at 3.0 % oxygen)
  • Flue gas, dry: CO2 10.25 %, O2 3.000 %; wet: H2O 16.44 %; 19.68 lb per lb of fuel; water dew point 133.1 °F
  • Adiabatic flame temperature without dissociation 3,369 °F (3,728 °F with no excess air)
  • Stack loss 6.13 % dry gas + 11.10 % water from hydrogen = 17.23 %; combustion efficiency 82.77 % of the higher heating value
  • F factors from the composition: F_d 8,665, F_w 10,650, F_c 1,031 scf per million Btu (Table 19-2, natural gas: 8,710, 10,610, 1,040)
  • E = 30 × 1.194 × 10⁻⁷ × 8,665 × 20.9 ÷ (20.9 − 3) = 0.0362 lb per million Btu (0.0364 with the tabulated F_d)

Notes

The tool's default inputs: press Submit. No single document prints this case end to end: the composition and heating values are NETL's, the F factors and the emission equation are EPA's, and every other number is the tool's own, checked in test_combustion_flue_gas.php against an independent numerical model. The tip sheet's efficiency table, whose fuel analysis is not stated, reads 0.4 to 0.8 point lower than the tool. The flame temperature is an upper bound because dissociation is not modeled.