Tools › Civil and Geotechnical › Design Loads › Earthquake Response Spectrum › Example
Pacoima Dam 1971: a record above 1 g, the base shear of a 1.5 s structure and a design spectrum drawn over it
| Tool | Earthquake Response Spectrum |
| Source | National Geophysical Data Center (1996). Earthquake Strong Motion CD-ROM Collection, Volume 1. National Oceanic and Atmospheric Administration, Boulder, CO. Data set USACA01, file 121 (Caltech corrected accelerogram IIC041, Pacoima Dam, San Fernando earthquake of February 9, 1971, component S16E) and data set USACA09, file 121. Design spectrum shape: Building Seismic Safety Council (2004). NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, Part 1: Provisions. FEMA 450, Section 3.3.4. |
| Level | Undergraduate |
Problem
The S16E accelerogram at Pacoima Dam in the San Fernando earthquake of February 9, 1971 (2,091 samples at 0.02 s) peaks above 1 g. Find the peak drift and the elastic base shear of a 250 kip one-story structure with a period of 1.5 s and 5 % damping, and compare its pseudo-acceleration with a two-parameter design spectrum with S_DS = 1.5 g, S_D1 = 0.9 g and T_L = 8 s.
Inputs to Enter
- Record: 2,091 accelerations in cm/s², time step 0.02 s; initial velocity 1.22996 cm/s, initial displacement 0.42512 cm (file header)
- Damping 5 %, period to show 1.5 s, weight 250 kip
- Design spectrum overlay: S_DS 1.5 g, S_D1 0.9 g, T_L 8 s (illustrative values, not those of a site)
Answers
- PGA = 37.67 ft/s² = 1.171 g at 7.74 s (file header 1,148.06 cm/s²); significant duration 7.04 s
- ω_n = 2π / 1.5 = 4.189 rad/s; S_d = 18.29 in at 6.0 s (published 18.3 in)
- S_a = 4.189² × 1.524 ft = 26.74 ft/s²; C_s = 26.74 / 32.17 = 0.8312 (published absolute acceleration 0.836 g)
- Base shear V_b = 0.8312 × 250 = 207.8 kip
- The structure sees 0.71 times the peak ground acceleration: at 1.5 s it is beyond the strongest part of the spectrum, which peaks at 0.379 s with 2.97 g
- Design spectrum at 1.5 s: S_D1 / T = 0.9 / 1.5 = 0.6 g; the record gives 1.39 times that value
Notes
Open this case in the tool: /analysis-tools/civil/loads/earthquake-response-spectrum/?try=pacoima-dam-1971. The comparison with the design curve is of one record with one smooth curve built from illustrative values: it is not a code check, and a design force would also be divided by a response modification factor for ductility.
More Examples for This Tool
- El Centro 1940: response of a 1 s, 5 % damped structure and the spectrum of the record
- Olympia 1949: a long record, its significant duration and a 0.5 s structure
- Golden Gate Park 1957: a short, sharp record and a stiff 0.2 s structure
- A sine at resonance: the 1 / (2ζ) amplification by Newmark's method