Tools › Civil and Geotechnical › Design Loads › Earthquake Response Spectrum › Example
Golden Gate Park 1957: a short, sharp record and a stiff 0.2 s structure
| Tool | Earthquake Response Spectrum |
| Source | National Geophysical Data Center (1996). Earthquake Strong Motion CD-ROM Collection, Volume 1. National Oceanic and Atmospheric Administration, Boulder, CO. Data set USACA01, file 044 (Caltech corrected accelerogram IIA015, San Francisco Golden Gate Park, San Francisco earthquake of March 22, 1957, component S80E) and data set USACA09, file 044. |
| Level | Graduate |
Problem
The S80E accelerogram at Golden Gate Park in the San Francisco earthquake of March 22, 1957 is a brief burst of high-frequency motion (1,994 samples at 0.02 s, given here in g). Find the response of a stiff structure with a period of 0.2 s and 5 % damping and note how the time step of the record limits the answer.
Inputs to Enter
- Record: 1,994 accelerations in g (the file values in cm/s² divided by 980.665, five decimals), time step 0.02 s; initial velocity −0.5292 cm/s, initial displacement 0.29477 cm (file header)
- Damping 5 %, period to show 0.2 s, weight 100 kip
- Spectrum from 0.04 to 2 s, 86 periods
Answers
- PGA = 3.373 ft/s² = 0.1048 g at 1.44 s (file header 102.80 cm/s²); significant duration 3.13 s
- ω_n = 2π / 0.2 = 31.42 rad/s; each 0.02 s record step is divided in three (h = 0.006667 s) so that the period holds at least 25 steps
- S_d = 0.1275 in at 2.013 s; read only at the record's own 0.02 s samples the same solution gives the published 0.122 in
- S_a = 31.42² × 0.01063 ft = 10.49 ft/s²; C_s = 0.3260, 3.11 times the peak ground acceleration (published absolute acceleration 0.322 g); V_b = 32.60 kip
- The spectrum peaks at 0.22 s with 0.389 g
Notes
Open this case in the tool: /analysis-tools/civil/loads/earthquake-response-spectrum/?try=golden-gate-1957. A 0.2 s period holds only ten samples of this record, the limit below which the tool warns that the spectrum depends on how the record was sampled: the 4 % gap between 0.1275 in and the published 0.122 in is the peak that falls between samples.
More Examples for This Tool
- El Centro 1940: response of a 1 s, 5 % damped structure and the spectrum of the record
- Pacoima Dam 1971: a record above 1 g, the base shear of a 1.5 s structure and a design spectrum drawn over it
- Olympia 1949: a long record, its significant duration and a 0.5 s structure
- A sine at resonance: the 1 / (2ζ) amplification by Newmark's method