Tools › Fluids and Heat Transfer › Thermodynamic Cycles › Thermodynamic Process Analyzer › Example

Steam nozzle from 100 psia and 500 °F to 1 atm at 90 % efficiency

ToolThermodynamic Process Analyzer
SourceU.S. Department of Energy (1992). DOE Fundamentals Handbook: Thermodynamics, Heat Transfer, and Fluid Flow, Volume 1 of 3. DOE-HDBK-1012/1-92, U.S. Department of Energy, Washington, DC. Module HT-01, pp. 76–77, Example 3 (inlet state, velocity, flow and inlet entropy).
LevelUndergraduate

Problem

Steam enters a nozzle at 100 psia and 500 °F with a velocity of 10 ft/sec and a flow of 10,000 lbm/hr (the inlet of the handbook's second-law example) and expands to 1 atm. For a nozzle efficiency of 90 % (an added, illustrative value) find the exit velocity, the exit state and the exit area.

Inputs to Enter

  • Water and steam, nozzle; units °F and Btu/lb; state 1: 100 psia (689.5 kPa), 500 °F; inlet velocity 10 ft/s
  • Exit pressure 14.696 psia (101.325 kPa), efficiency 90 %, mass flow 2.778 lb/s (1.26 kg/s)
Open the Thermodynamic Process Analyzer tool

Answers

  • Inlet entropy 1.7089 Btu/(lb·°R) (handbook 1.7088); h_1 = 1,279.3 Btu/lb
  • Ideal exit: x_2s = 0.9670, isentropic enthalpy drop 161.07 Btu/lb; actual drop 0.90 · 161.07 = 144.96 Btu/lb, h_2 = 1,134.4 Btu/lb
  • Exit velocity √(10² + 2 · 144.96 · 25,037) = 2,694 ft/s (821.2 m/s), against 2,840 ft/s ideal; exit at 212.0 °F with x_2 = 0.9836
  • Exit area 3.91 in² (25.25 cm²)

Notes

Open this case in the tool: /analysis-tools/thermal-fluids/cycles/thermo-process-analyzer/?try=steam-nozzle. The handbook's own example ends at 300 °F and asks only for the entropy rise (1.8158 − 1.7088 = 0.107 Btu/lbm-°R, 1,070 Btu/hr-°R); the tool gives 1.8160 and 1.7089 for those two states. The exit pressure and efficiency used here are not from the handbook.

More Examples for This Tool