Tools › Electrical and Controls › Electric Machines › Induction Motor Equivalent Circuit › Example

Wound-rotor induction motor: ten times the rotor resistance moves the pull-out torque to standstill without changing it

ToolInduction Motor Equivalent Circuit
Sourceoriginal
LevelUndergraduate

Problem

The 460 V, 60 Hz, four-pole motor of the previous example (R1 = 0.22 Ω, X1 = 0.55 Ω, X2 = 0.75 Ω, Xm = 18 Ω) has its rotor resistance raised from 0.13 Ω to 1.30 Ω by external resistors. Compare the starting torque and current and the pull-out point with the original machine, and find the operating point at ten times the original slip (24 %).

Inputs to Enter

  • Line voltage 460 V, 60 Hz, 4 poles, wye; R1 0.22, X1 0.55, R2 1.30, X2 0.75, Xm 18 Ω; rotational losses 500 W; slip 24 %
  • Comparison curve: the same machine with R2 = 0.13 Ω
Open the Induction Motor Equivalent Circuit tool

Answers

  • Pull-out slip 1.30 / √(0.2071² + 1.286²) = 0.9979: the peak sits at standstill; pull-out torque 350.0 N·m, unchanged (R2 is not in its formula)
  • Starting torque 350.0 N·m against 77.72 N·m (4.50 times); starting current 135.8 A against 201.9 A (0.673 times)
  • At 24 % slip R2 / s = 1.30 / 0.24 = 5.417 Ω, the same as 0.13 / 0.024: the same 48.43 A, power factor 0.880, 33,970 W input and 32,420 W across the air gap
  • Rotor copper loss 0.24 × 32,420 = 7,781 W (ten times as much); output 24,140 W at 1,368 rpm; shaft torque 168.5 N·m; efficiency 71.06 %

Notes

Open this case in the tool: /analysis-tools/electrical/machines/induction-motor-equivalent-circuit/?try=rotor-resistance-moves-the-peak. An illustrative machine. The price of the high starting torque is the rotor copper loss, which is the fraction s of the air-gap power.

More Examples for This Tool