Tools › Electrical and Controls › Electric Machines › Induction Motor Equivalent Circuit › Example
Induction motor circuit parameters from the DC, no-load and blocked-rotor tests, full circuit against the classroom short form
| Tool | Induction Motor Equivalent Circuit |
| Source | original |
| Level | Undergraduate |
Problem
A 208 V, 60 Hz, four-pole, wye-connected induction motor gives these readings. DC test between two terminals: 12.0 V, 20.0 A. No-load test at 208 V, 60 Hz: 8.61 A, 377 W. Blocked-rotor test at 15 Hz: 23.35 V, 25.0 A, 913 W. Find the per-phase circuit with the leakage reactance split equally, then the operating point at 3 % slip.
Inputs to Enter
- DC test 12.0 V, 20.0 A; no-load test 208 V, 8.61 A, 377 W; blocked-rotor test 23.35 V, 25.0 A, 913 W at 15 Hz
- Line voltage 208 V, 60 Hz, 4 poles, wye; 50 % of the leakage reactance to the stator; slip 3 %
Answers
- R1 = 12.0 / (2 × 20.0) = 0.3000 Ω
- No load: Q = √(3,101.9² − 377²) = 3,078.9 var; X1 + Xm = 3,078.9 / (3 × 8.61²) = 13.84 Ω; rotational losses 377 − 3 × 8.61² × 0.30 = 310.3 W
- Blocked rotor: |Z| = 13.48 / 25.0 = 0.5392 Ω; R = 913 / (3 × 25.0²) = 0.4869 Ω; X = 0.2317 Ω at 15 Hz = 0.9268 Ω at 60 Hz
- Full circuit (magnetizing branch kept): X1 = X2 = 0.4490 Ω, R2 = 0.2003 Ω, Xm = 13.40 Ω; classroom short form: X1 = X2 = 0.4634 Ω, R2 = 0.1869 Ω, Xm = 13.48 Ω
- At 3 % slip (1,746 rpm), full-circuit values: 19.00 A at a power factor of 0.850; input 5,818 W; output 5,018 W; shaft torque 27.45 N·m; efficiency 86.25 %
- Starting torque 42.07 N·m at 118.7 A; pull-out torque 88.49 N·m
Notes
Open this case in the tool: /analysis-tools/electrical/machines/induction-motor-equivalent-circuit/?try=circuit-from-three-tests. Illustrative readings, made from a machine with R1 0.30, X1 = X2 0.45, R2 0.20 and Xm 13.5 Ω. The equal split of the leakage reactance is an assumption; the tests give only the sum.
More Examples for This Tool
- 460 V four-pole induction motor: operating point at 2.4 % slip, and a start that takes 4.2 times the current for 0.45 times the torque
- Wound-rotor induction motor: ten times the rotor resistance moves the pull-out torque to standstill without changing it
- Induction motor on 80 % voltage: every point of the torque-speed curve falls to 64 %