Tools › Units › Calculators › Calc Sheet › Example
A tie rod in mixed units: 12 kN on a 0.5 in rod, stress in MPa and ksi, stretch in mm
| Tool | Calc Sheet |
| Source | Original case; conversion factors from Thompson, A., and Taylor, B. N. (2008). Guide for the Use of the International System of Units (SI). NIST Special Publication 811, National Institute of Standards and Technology, Gaithersburg, MD. Appendix B.8 (inch, foot, pound-force per square inch). |
| Level | Undergraduate |
Problem
A steel tie rod 0.5 in in diameter and 3 ft long carries 12 kN. The modulus is 200 GPa and the yield strength 250 MPa (illustrative values). Find the axial stress in MPa and in ksi, the factor of safety on yield and the elongation in millimeters, keeping every quantity in the unit it was given in.
Inputs to Enter
- Sheet lines: P = 12 kN, d = 0.5 in, L = 3 ft, E = 200 GPa, F_ty = 250 MPa
- A = pi * d^2 / 4; sigma = P / A in MPa; sigma in ksi; FS = F_ty / sigma; check sigma < F_ty
- delta = P * L / (A * E) in mm; delta in in; check delta < L / 500
- Last line, on purpose: wrong = P + d
Answers
- A = π · (0.5000 in)² / 4 = 0.1963 in²
- σ = 12.00 kN / 0.1963 in² = 94.73 MPa = 13.74 ksi (12,000 N / 1.2668 × 10⁻⁴ m²)
- FS = 250.0 MPa / 94.73 MPa = 2.639; check σ < F_ty: ratio 0.379, OK
- δ = 12.00 kN · 3.000 ft / (0.1963 in² · 200.0 GPa) = 0.4331 mm = 0.01705 in; limit L / 500 = 1.829 mm, ratio 0.237, OK
- The line wrong = P + d is refused on its own line: a force and a length cannot be added; the rest of the sheet is unaffected
Notes
Open this case in the tool: /analysis-tools/units/calculators/calc-sheet/?try=tie-rod-mixed-units. It is also the sheet the tool opens with; press Submit. The numbers were checked against a separate Python computation with the exact SP 811 definitions (test_calc_sheet.php).
More Examples for This Tool
- Bolted lap joint: bolt shear, plate bearing and the governing capacity with entered allowables
- Darcy-Weisbach pressure drop of 12 L/s in a 100 mm pipe with an entered friction factor
- Heat loss through a three-layer wall: resistances in series, overall coefficient, watts and kWh per day
- A 180 kg machine on four 45 N/mm springs: static deflection, natural frequency and transmissibility