Tools › Units › Calculators › Calc Sheet › Example
Darcy-Weisbach pressure drop of 12 L/s in a 100 mm pipe with an entered friction factor
| Tool | Calc Sheet |
| Source | Original case; the friction factor and the water properties are entered illustrative values. |
| Level | Undergraduate |
Problem
Water (998 kg/m³, 0.001 Pa·s) flows at 12 L/s through 150 m of straight pipe of 100 mm inside diameter. With an entered Darcy friction factor of 0.02, find the mean velocity, the Reynolds number, the friction pressure drop in kPa and the same loss as a head of water.
Inputs to Enter
- Q = 12 L/s, D = 100 mm, L_p = 150 m, f = 0.02, rho = 998 kg/m^3, mu = 0.001 Pa-s
- A = pi * D^2 / 4 in m^2; v = Q / A in m/s; Re = rho * v * D / mu; check Re > 4000; check v < 3 m/s
- Deltap = f * (L_p / D) * rho * v^2 / 2 in kPa; h_f = Deltap / (rho * g_0) in m
Answers
- A = 0.007854 m²; v = 12.00 L/s / 0.007854 m² = 1.528 m/s
- Re = 998 · 1.528 · 0.1 / 0.001 = 152,500 (a pure number: the units cancel on the sheet), turbulent
- Δp = 0.02 · (150 m / 100 mm) · 998 kg/m³ · (1.528 m/s)² / 2 = 34.95 kPa
- h_f = 34.95 kPa / (998 kg/m³ · 9.807 m/s²) = 3.571 m
Notes
Open this case in the tool: /analysis-tools/units/calculators/calc-sheet/?try=pipe-pressure-drop. The length ratio 150 m / 100 mm is reduced to 1,500 by the unit handling; typed as plain numbers it is the classic factor-of-1,000 slip. For a friction factor computed from roughness see Pipe Pressure Drop.
More Examples for This Tool
- A tie rod in mixed units: 12 kN on a 0.5 in rod, stress in MPa and ksi, stretch in mm
- Bolted lap joint: bolt shear, plate bearing and the governing capacity with entered allowables
- Heat loss through a three-layer wall: resistances in series, overall coefficient, watts and kWh per day
- A 180 kg machine on four 45 N/mm springs: static deflection, natural frequency and transmissibility