Tools › Units › Calculators › Calc Sheet › Example

Darcy-Weisbach pressure drop of 12 L/s in a 100 mm pipe with an entered friction factor

ToolCalc Sheet
SourceOriginal case; the friction factor and the water properties are entered illustrative values.
LevelUndergraduate

Problem

Water (998 kg/m³, 0.001 Pa·s) flows at 12 L/s through 150 m of straight pipe of 100 mm inside diameter. With an entered Darcy friction factor of 0.02, find the mean velocity, the Reynolds number, the friction pressure drop in kPa and the same loss as a head of water.

Inputs to Enter

  • Q = 12 L/s, D = 100 mm, L_p = 150 m, f = 0.02, rho = 998 kg/m^3, mu = 0.001 Pa-s
  • A = pi * D^2 / 4 in m^2; v = Q / A in m/s; Re = rho * v * D / mu; check Re > 4000; check v < 3 m/s
  • Deltap = f * (L_p / D) * rho * v^2 / 2 in kPa; h_f = Deltap / (rho * g_0) in m
Open the Calc Sheet tool

Answers

  • A = 0.007854 m²; v = 12.00 L/s / 0.007854 m² = 1.528 m/s
  • Re = 998 · 1.528 · 0.1 / 0.001 = 152,500 (a pure number: the units cancel on the sheet), turbulent
  • Δp = 0.02 · (150 m / 100 mm) · 998 kg/m³ · (1.528 m/s)² / 2 = 34.95 kPa
  • h_f = 34.95 kPa / (998 kg/m³ · 9.807 m/s²) = 3.571 m

Notes

Open this case in the tool: /analysis-tools/units/calculators/calc-sheet/?try=pipe-pressure-drop. The length ratio 150 m / 100 mm is reduced to 1,500 by the unit handling; typed as plain numbers it is the classic factor-of-1,000 slip. For a friction factor computed from roughness see Pipe Pressure Drop.