Tools › Units › Calculators › Calc Sheet › Example
Bolted lap joint: bolt shear, plate bearing and the governing capacity with entered allowables
| Tool | Calc Sheet |
| Source | Original case; the allowable stresses are entered illustrative values, not taken from a design code. |
| Level | Undergraduate |
Problem
Four 0.75 in bolts in single shear join two plates, the thinner 0.375 in thick, under a joint load of 24 kip. With an entered allowable bolt shear stress of 24 ksi and an allowable bearing stress of 58 ksi, check bolt shear and plate bearing and find the capacity of the joint.
Inputs to Enter
- P = 24 kip, n = 4, d = 0.75 in, t = 0.375 in, F_v = 24 ksi, F_p = 58 ksi
- A_b = pi * d^2 / 4; V = P / n; f_v = V / A_b in ksi; check f_v <= F_v
- f_p = V / (d * t) in ksi; check f_p <= F_p
- P_shear = n * A_b * F_v in kip; P_bearing = n * d * t * F_p in kip; P_allow = min(P_shear, P_bearing); U = P / P_allow
Answers
- A_b = 0.4418 in²; V = 24.00 kip / 4 = 6.000 kip
- f_v = 6.000 kip / 0.4418 in² = 13.58 ksi against 24 ksi: ratio 0.566, OK
- f_p = 6.000 kip / (0.7500 in · 0.3750 in) = 21.33 ksi against 58 ksi: ratio 0.368, OK
- P_shear = 42.41 kip, P_bearing = 65.25 kip, P_allow = min = 42.41 kip; utilization 0.5659
Notes
Open this case in the tool: /analysis-tools/units/calculators/calc-sheet/?try=bolt-shear-bearing. The sheet checks the units and the arithmetic of the lines as typed; block shear, net section, edge distance and the code's own strength values are not part of it.
More Examples for This Tool
- A tie rod in mixed units: 12 kN on a 0.5 in rod, stress in MPa and ksi, stretch in mm
- Darcy-Weisbach pressure drop of 12 L/s in a 100 mm pipe with an entered friction factor
- Heat loss through a three-layer wall: resistances in series, overall coefficient, watts and kWh per day
- A 180 kg machine on four 45 N/mm springs: static deflection, natural frequency and transmissibility