Tools › Electrical and Controls › Control Systems › Transfer Function Analyzer › Example

Standard underdamped second-order system 1 / (s² + s + 1): overshoot, peak time and settling time against the closed forms

ToolTransfer Function Analyzer
SourceOriginal case; closed forms of the standard second-order step response (overshoot 100 exp(−ζπ / √(1 − ζ²)), peak time π / ω_d).
LevelUndergraduate

Problem

A system has the transfer function G(s) = 1 / (s² + s + 1), that is ω_n = 1 rad/s and ζ = 0.5. Find its poles and the rise time, peak time, percent overshoot and 2 % settling time of its unit-step response.

Inputs to Enter

  • Numerator 1; denominator 1 1 1; gain K = 1
  • The whole system, as given; input signal: unit step
Open the Transfer Function Analyzer tool

Answers

  • Poles −0.5 ± j 0.866: ω_n = 1 rad/s, ζ = 0.5
  • Overshoot 100 exp(−0.5π / √0.75) = 16.30 %; peak time π / 0.866 = 3.628 s (measured 16.3 % at 3.628 s)
  • Rise time 1.638 s; settling time 8.076 s (the rule 4 / (ζ ω_n) gives 8 s)
  • Bandwidth 1.272 rad/s; as a loop it would have a phase margin of 90° at 1 rad/s and an unlimited gain margin

Notes

Open this case in the tool: /analysis-tools/electrical/controls/transfer-function-analyzer/?try=second-order. The test script checks the same closed forms for ζ = 0.05, 0.2, 0.5 and 0.707.

More Examples for This Tool