Tools › Structures › Composites › Composite Bearing-Bypass › Example

Bolted composite coupon, half the load in bearing: Eisenmann's strength model at the tested failing load

ToolComposite Bearing-Bypass
SourceEisenmann, J. R. (1976). "Bolted Joint Static Strength Model for Composite Materials." In Third Conference on Fibrous Composites in Flight Vehicle Design, Part II, NASA Technical Memorandum X-3377, National Aeronautics and Space Administration, Washington, DC, pp. 563–603. Table I, Figure 5 and Figure 10.
LevelProfessional

Problem

A T300/5208 coupon of half 0° and half ±45° plies, 2.25 in wide with a 0.375 in fastener hole (W/D = 6), is pulled along its 0° direction with half of the load taken out through the fastener. The paper's three coupons failed at an average gross stress of 31.44 ksi. Apply that load and find the margin and the failure point.

Inputs to Enter

  • Laminate: E_x 11.9 Msi, E_y 3.55 Msi, G_xy 3.08 Msi, ν_xy 0.678, thickness 0.168 in, 50 % 0° and 50 % ±45° plies, offset angle 0; strength data T300/5208 correlations; 45° bearing factor corrected
  • One fastener: D 0.375 in, spacing along X 3.75 in, along Y 2.25 in (the coupon width), edge distances blank; fastener force F_X 5,942 lb, bypass N_X 2,641 lb/in (ultimate)
Open the Composite Bearing-Bypass tool

Answers

  • σ_bx = 5,942 / (0.375 × 0.168) = 94.32 ksi, σ_tx = 2,641 / 0.168 = 15.72 ksi; for loads along x no edge (E/D = 5, the largest tabulated) and W/D = 6
  • Strengths and lengths: points 3, 7 tension 116.1 ksi, a = 0.03975 in; 45° points 58.91 ksi, a = 0.03483 in; points 1, 5 22.90 ksi, a = 0.1210 in
  • Point 3 (net section): λ f = 2.276 for tension and 0.868 for bearing, σ_3 = 2.276 × 15.72 + 0.868 × 94.32 = 117.7 ksi against 116.1 ksi: M.S. = −0.01 (ULT), the critical point
  • Point 2: σ_2 = 56.81 ksi against 58.91 ksi, M.S. = +0.04; point 1: 18.32 ksi against 22.90 ksi, M.S. = +0.25
  • With the 45° bearing factor as printed in the paper, point 2 governs at M.S. = −0.14

Notes

Open the tool with the Try this case 'Paper coupon, 50% bearing'. A margin of about zero at the tested failing load is the model reproducing the test; the paper reports failures at points 3 and 7 for this case. The coupon thickness and laminate moduli are not given in the paper: the thickness is a round value (it cancels) and the moduli are laminate-theory values for T300/5208 of that period. Values from test_composite_bearing_bypass.php and the library.