Tools › Numerical Methods › Data Tools › Plot Digitizer › Example

Pump curve read from a picture, then interpolated at three flows

ToolPlot Digitizer
SourceOriginal case: an illustrative pump curve H = 60 − 0.012 Q² (m, L/s) drawn by the tool's own script and read back; values from test_plot_digitizer.php.
LevelUndergraduate

Problem

A pump head-flow curve is printed on linear axes, flow 0 to 60 L/s across 522 pixels and head 0 to 80 m up 328 pixels. Eleven markers on it are picked, 6 L/s apart. Read their values, then find the head at 15, 25 and 45 L/s by straight-line interpolation between the neighboring points, and judge the error.

Inputs to Enter

  • X1 at pixel (84, 372), value 0; X2 at (606, 372), value 60; Y1 at (84, 372), value 0; Y2 at (84, 44), value 80; both axes linear
  • Eleven points from (84, 126) to (606, 303); Advanced: interpolate at x = 15, 25, 45; resampled points 7
Open the Plot Digitizer tool

Answers

  • One pixel is worth 60 / 522 = 0.115 L/s and 80 / 328 = 0.244 m
  • Third marker (188, 133): r_x = 104 / 522 = 0.19923, r_y = 239 / 328 = 0.72866, so Q = 11.95 L/s, H = 58.29 m (drawn at 12 L/s, 58.27 m)
  • Interpolated head: 57.20 m at 15 L/s, 52.53 m at 25 L/s, 35.61 m at 45 L/s (the formula gives 57.30, 52.50 and 35.70 m)
  • Resampled at 0, 10, ..., 60 L/s: 60, 58.69, 55.14, 49.27, 40.61, 30.05, 16.83 m (formula: 60, 58.8, 55.2, 49.2, 40.8, 30, 16.8 m)

Notes

Open this case in the tool: /analysis-tools/numerical-methods/data-tools/plot-digitizer/?try=pump-curve. The interpolated values are within 0.1 m of the curve: part of that is the one-pixel reading error (0.24 m per pixel) and part the straight line cutting across a curve that bows outward, at most 0.012 × 6² / 4 = 0.11 m here. Closer points reduce the second part only.

More Examples for This Tool