Tools › Electrical and Controls › Signal Processing › Signal Analysis (FFT and PSD) › Example
Ring-down of a 40 Hz resonance: damping ratio from the half-power width of the spectrum peak
| Tool | Signal Analysis (FFT and PSD) |
| Source | Original case (a free decay 5 exp(−ζ ω_n t) sin(ω_d t) mm with f_n = 40 Hz and ζ = 0.02, sampled at 500 Hz), checked against the closed forms f_d = f_n √(1 − ζ²) and Δf = 2 ζ f_n in test_signal_analysis.php. |
| Level | Undergraduate |
Problem
A structure struck once rings down at about 40 Hz. Its displacement is recorded for 4.096 s at 500 samples a second. Estimate the damped frequency and the damping ratio from the spectrum.
Inputs to Enter
- 2,048 values in mm, sample rate 500 Hz
- Advanced mode: window rectangular, no trend removed, amplitude spectrum, logarithmic axes
Answers
- Resolution Δf = 500 / 2,048 = 0.2441 Hz; Nyquist frequency 250 Hz
- Peak at 39.99 Hz (parabola through three lines; damped frequency 40 √(1 − 0.02²) = 39.992 Hz)
- Half-power width 1.619 Hz, 6.6 lines wide, so the lines resolve the peak
- ζ = width / (2 f) = 1.619 / (2 × 39.99) = 0.0202 (true value 0.02)
- Crest factor 8.79 and kurtosis 30.8: a transient, not a steady signal; Parseval's ratio is 1.0000 with the rectangular window
Notes
Open this case in the tool: /analysis-tools/electrical/signals/signal-analysis/?try=ring-down. The record must hold the whole decay and the window must be rectangular: a Hann window would taper away the start of the ring-down, where most of the signal is. The height of the peak depends on the record length and is not the amplitude of a tone.