Tools › Civil and Geotechnical › Foundations › Drilled Shaft Capacity › Method
Drilled Shaft Capacity: Method
Open the Drilled Shaft Capacity tool
Drilled Shaft Capacity
What the tool does
It computes the axial resistance of one straight-sided drilled shaft (bored pile, drilled pier, caisson) in a layered profile of soil and rock by Chapter 10 of the Federal Highway Administration's drilled shaft manual, Geotechnical Engineering Circular No. 10 in its 2018 edition (FHWA-NHI-18-024). The 2010 edition (FHWA-NHI-10-016) is not used. Each layer gives a nominal side resistance R_SN = π B Δz f_SN (Eq. 10-3) and the layer at the tip gives a nominal base resistance R_BN = (π B² / 4) q_BN (Eq. 10-4). The page prints them layer by layer, applies the manual's resistance factors or factors of safety, compares the result with the entered loads and repeats the calculation for other tip depths. Driven piles are a different tool on this site, Pile Capacity and Lateral Load, which also holds lateral analysis, group efficiency and downdrag.
Conventions
Depths are measured downward from the ground surface (the mudline), where the top of the shaft is. Layers are entered from the surface down and the last one continues below its entered bottom. A unit weight is the total weight above the groundwater level and the saturated weight below it; the effective stress below the groundwater level uses the entered weight less 62.4 lb/ft³ (9.81 kN/m³ in SI units, which makes SI results very slightly lower). Atmospheric pressure p_a is 2,116 psf (101.3 kPa), as the manual writes it. Every stress-dependent quantity of a layer is evaluated once, at the middle of the length of that layer that gives resistance, which is how the manual's examples work; a thick layer whose properties change with depth should be entered as several layers.
Cohesionless soil: the β-method
f_SN = β σ′_v with β = K tan φ′ (Eqs. 10-5 to 10-7), the interface friction angle being taken equal to φ′. K is the at-rest coefficient K_o = (1 − sin φ′) OCR^(sin φ′), not above the passive coefficient K_p = tan²(45° + φ′/2) (Eqs. 10-9, 10-10). The overconsolidation ratio is OCR = σ′_p / σ′_v (Eq. 10-8) with the preconsolidation stress from the blow count: σ′_p = 0.47 N_60^m p_a with m = 0.6 for clean sand and 0.8 for silty sand to sandy silt (Eq. 10-11), or 0.15 N_60 p_a for gravelly soil (Eq. 10-12). An OCR below 1 is taken as 1, as the manual's Appendix A tables do. Above a depth of 7.5 ft β keeps its value at that depth (section 10.3.5.1). When no friction angle is entered, φ′ = 27.5 + 9.2 log (N_1)_60 with (N_1)_60 = N_60 √(p_a / σ′_vo) (Appendix A, Eqs. A-1 and A-2); the correction factor is not taken above 2, which is what Table A-3 of the manual shows at shallow depth although the text does not state it.
Cohesive soil: the α-method
f_SN = α s_u with α = 0.30 + 0.17 / (s_u / p_a) (Eqs. 10-15, 10-18), where s_u is the strength from consolidated isotropically undrained triaxial compression (CIUC). A strength from unconsolidated undrained (UU) or unconfined compression (UC) tests is first divided by 0.911 + 0.499 log(s_u / σ′_vo) or 0.893 + 0.513 log(s_u / σ′_vo) (Eqs. 10-17, 10-16), σ′_vo being the effective stress of the existing ground at the middle of the layer. Side resistance in cohesive soil is neglected over the top 5 ft (section 10.3.5.2; an input). The 2018 manual neglects nothing above the base; an input allows a length there for agencies whose practice differs.
Two bounds are this tool's own and are not in the manual. Below s_u = 0.243 p_a the regression of Eq. 10-18 gives a unit side resistance above the strength itself, so α is not taken above 1. And the strength ratio of Eqs. 10-16 and 10-17 is not taken below 0.5, where the correlation is far outside its data. Each prints a note when it acts.
Rock sockets
Normal socket: f_SN = C p_a √(q_u / p_a) with C = 1.0 (Eq. 10-21), q_u being the uniaxial compressive strength of intact core and not taken above the concrete strength f′_c. Rock that caves or needs casing or grout-ahead drilling: f_SN = 0.65 α_E p_a √(q_u / p_a) (Eq. 10-22) with the joint modification factor α_E of Table 10-3, entered per layer (closed joints 1.00, 0.85, 0.60, 0.50, 0.45 and open or gouge-filled joints 0.85, 0.55, 0.55, 0.50, 0.45 at RQD 100, 70, 50, 30 and 20 %). The manual reports a mean C of 1.9 for artificially roughened sockets and asks that any value above 1.0 be verified by load tests.
Base resistance
Cohesionless soil: q_BN = 0.60 N_60 in tons per square foot, not above 30 tsf (Eq. 10-14), with the uncorrected N_60 averaged over two diameters below the base; the relation holds for N_60 up to 50 and describes the resistance at a settlement of 5 % of the base diameter. Cohesive soil: q_BN = N*_c s_u (Eq. 10-19) with N*_c = 6.5, 8.0 and 9.0 at s_u = 500, 1,000 and 2,000 psf or more (Table 10-2, interpolated, 6.5 held below 500 psf), multiplied by (2/3)(1 + D / (6 B)) when the embedment D is less than 3 B (Eq. 10-20). Rock: q_BN = N*_cr q_u with N*_cr = 2.5 for massive or tightly jointed rock (Eq. 10-23), or for a fractured rock mass the expression of Turner and Ramey with the Hoek-Brown parameters (Eqs. 10-25 to 10-29): m_b = m_i exp((GSI − 100) / 28), s = exp((GSI − 100) / 9), a = 1/2 + (e^(−GSI/15) − e^(−20/3)) / 6, A = σ′_vb + q_u (m_b σ′_vb / q_u + s)^a and q_BN = A + q_u (m_b A / q_u + s)^a, limited to N*_cr q_u. Under LRFD the factored base resistance in rock is also not taken above the factored bearing resistance of the shaft concrete, φ 0.85 f′_c A m, as Illustrative Example 10-4 of the manual checks it.
Resistance factors, factors of safety and margins
LRFD (Eq. 10-2): Σ φ_S R_SN + φ_B R_BN is compared with the factored load. The defaults are Table 8-4 of the manual: side resistance 0.55 in cohesionless soil, 0.45 in cohesive soil, 0.50 in rock; base resistance 0.50, 0.40 and 0.50; for uplift each side factor is 0.10 lower. The text of section 10.3.5.3 gives 0.55 for side resistance in rock where the table prints 0.50; the lower value is the default. ASD: the side resistance is divided by its factor of safety and the base resistance by its own; the defaults 2.5 and 2.75 are the factors of safety to which the manual says its resistance factors were fitted, not an ASD procedure of the manual. The margin printed is the design resistance divided by the entered load, less one.
Uplift is resisted by side resistance alone (Eq. 10-32). The manual treats the weight of the shaft as a load effect that reduces the demand; this page prints the effective weight and leaves it out of the margin.
Scour
An entered scour depth removes the soil above the scour line: it gives no resistance and no overburden. Following the manual's Appendix A, β keeps the value of the existing ground and f_SN = β σ′_v uses the stress after scour; cohesive soil and rock keep their unit resistances (section 10.5.5). Where scour removes part of a layer, the tool evaluates β at the middle of the remaining length; the Appendix A table keeps the β of the whole layer, which is higher, so the tool is the lower of the two there. The reduction of stress around a local scour hole (section 10.5.4) is not modeled.
Service limit state: settlement
The manual's first-order method (section 10.3.7) uses two normalized load-displacement curves, its Figure 10-10 (after Chen and Kulhawy): axial force as a percentage of the failure threshold against the displacement of the shaft head as a percentage of the diameter, one curve for a base in cohesive soil and one for a base in cohesionless soil. The failure threshold is R_SN + R_BN, with R_BN multiplied by 0.71 when the base is in cohesionless soil (which brings Eq. 10-14 from 5 % to 4 % of the diameter), and the axial force is the load at the head plus the effective weight of the shaft (Eq. 10-31).
The manual states the curves in words only at three places: a straight line from zero to 50 % of the threshold at 0.4 % of the diameter, the threshold (100 %) at 4 %, and beyond it a constant 100 % for cohesive soil. It gives no equation for the curved part between 0.4 % and 4 % or for the rising line of the cohesionless curve beyond 4 %. Those are taken from the figure itself, which is a vector drawing in the manual's file: the coordinates of the drawn curves were read directly (not traced from pixels), calibrated on the tick marks of both axes and tabulated every 0.1 % of the diameter. The reading accuracy is about ± 0.5 % of the failure threshold, which is the amount by which the figure's own tick marks, guide lines and two drawings of the cohesionless curve disagree. The cohesionless curve runs straight from (4 %, 100 %) to the end of the drawing at (10 %, 158.7 %); the cohesive curve is drawn to 8.5 %.
The page gives the settlement under the service load, the load at the head that produces an entered tolerable settlement, R_service, and the service limit state check of Eq. 10-30 with the resistance factor 1.00 that Table 8-4 gives for Service I, and it plots the head load against settlement. Outside the drawn range (a displacement beyond 8.5 % or 10 % of the diameter, a force above the threshold on the cohesive curve or above 158.7 % on the cohesionless one) it prints a message and no value. Whatever the reading accuracy, the curves are averages of 56 (cohesive) and 46 (cohesionless) load-test data points with wide scatter; the manual calls the result a crude first-order estimate and limits it to diameters of 1 to 6.5 ft, depths of 16 to 200 ft and depth-to-diameter ratios of 5.8 to 56.4. With the tip in rock no settlement is estimated.
Appendix C of the manual also reprints the side and base load-transfer curves of the 1999 edition (Figures C-3 and C-4) "for historical reference". They are not used here: the 2018 edition prints no procedure for them and says Figure 10-10 replaces them, they are scanned images, and the panel printed as the base curve for cohesionless soil is a second copy of the side curve.
What it assumes
One vertical, straight-sided shaft of constant diameter, loaded along its axis, built with sound practice (clean base, stable sidewall, prompt concreting). Cohesive layers respond undrained and cohesionless layers drained. The properties entered are the mean values of each layer. Side and base resistance are added in full, as the manual does for strength limit states.
When it misleads
The correlations behind β rest on SPT blow counts, and the manual itself notes that the β-method resistance factor is a fit to a factor of safety, not a reliability calibration. Poor construction lowers the side resistance in sand (the manual mentions K falling to two-thirds of K_o or less) and can remove the base resistance altogether. The base resistance in sand and the full side resistance are reached at very different displacements, most of all in rock sockets, where the manual discusses neglecting one of the two. Cohesive intermediate geomaterials, clay shales, karst, expansive soil, liquefiable layers, downdrag, group action, lateral loading, belled shafts and the structural design of the shaft are outside the page. The default layers and loads are the manual's example, not a site; a real design needs the site investigation, and load tests where the manual calls for them.
Checks
The test script reproduces the manual's Illustrative Examples 10-1 to 10-6 and the two spreadsheets of its Appendix A. Appendix A Table A-5 is matched to the printed pound in every cohesionless layer and at the base. The examples of Chapter 10 are matched within 0.7 %, the differences being the manual's rounding of β to two digits before multiplying. An independent numerical script checks 30 random profiles. The digitized curves reproduce the manual's reading in Example 10-6 (93 % at 2.5 % of the diameter); in Appendix A the manual reads 78 % at 2.1 % on the cohesionless curve where the drawn curve passes 80 %. The Hoek-Brown expression has no printed number in the manual; it is compared with two points read from Figure 10-8 and with its closed-form limit for intact rock.
Notes on the source
Appendix A Table A-5 prints a cohesionless side resistance sum of 4,832,242 lb and a total of 9,932 kips; its five rows add to 5,357,017 lb, so the total with layer 1 is 10,457 kips. Illustrative Example 10-1 prints "2,288.4 psf (1.08)" where β is 0.98. Appendix A converts a UU strength with the UC equation and with 2,114 psf where the layer's effective stress is meant. Illustrative Example 10-5 mentions 890.1 kips in its text and 855.4 kips in its table and check.