Problem

A reservoir at grade 700 ft feeds a two-loop network through a pump rated 150 ft at 600 gal/min; eight Hazen–Williams pipes (C = 100) join six junctions and a tank whose water surface is at 834 ft. Find the flow, velocity and unit head loss of every pipe for the state shown in the manual's Figure 2.7 (junction demands at half their base values).

Inputs to Enter

  • Nodes (elevation ft, base demand gal/min): 2 (700, 0), 3 (710, 150), 4 (700, 150), 5 (650, 200), 6 (700, 150), 7 (700, 0); reservoir 1 at grade 700 ft; tank 8 at elevation 830 ft with a 4 ft level (grade 834 ft)
  • Pipes (from–to, length ft, diameter in), all C = 100: 1 (2–3, 3,000, 14), 2 (3–7, 5,000, 12), 3 (3–4, 5,000, 8), 4 (4–6, 5,000, 8), 5 (6–7, 5,000, 8), 6 (7–8, 7,000, 10), 7 (4–5, 5,000, 6), 8 (5–6, 7,000, 6)
  • Pump 9 from node 1 to node 2, single-point curve through 600 gal/min at 150 ft: h = 200 − 50 (Q/600)² ft
  • Friction formula Hazen–Williams; demand factor 0.5
Open the Pipe Network Solver tool (loaded with this example)

Answers

  • Flows, gal/min (tool = manual): pipe 1 617.42, pipe 2 382.51, pipe 3 159.91, pipe 4 29.34, pipe 5 −90.09, pipe 6 292.42, pipe 7 55.58, pipe 8 −44.42
  • Velocities, ft/s (manual 1.29, 1.09, 1.02, 0.19, 0.57, 1.19, 0.63, 0.50): tool 1.287, 1.085, 1.021, 0.187, 0.575, 1.195, 0.631, 0.504
  • Unit head losses, ft per 1,000 ft (manual 0.80, 0.69, 1.00, 0.04, 0.34, 1.03, 0.57, 0.38): tool 0.796, 0.695, 0.996, 0.043, 0.344, 1.027, 0.571, 0.377
  • Pump operating point 617.42 gal/min at 147.05 ft; 292.42 gal/min enters the tank; 5 gradient iterations

Notes

The tool's default inputs are this network; press Submit. Two details of the manual were settled by calculation: Figure 2.7 corresponds to the tank level of 4 ft entered on p. 19 (p. 14 says 3.5 ft) and to demands at 0.5 of Table 2.1, the first multiplier of the demand pattern added in the tutorial's next section. The manual prints no node grades or pressures for this state; those on the page are the tool's own.