Tools › Fluids and Heat Transfer › Conduction › Thermal Network Solver › Example
NASA's first SINDA model: a 1 m aluminum box in deep space with sunlight on one wall, −23.2 / −120.9 / −107.9 °C at steady state and after 50,000 s
| Tool | Thermal Network Solver |
| Source | Rickman, S. L. (2020). Building Your First SINDA Model. NASA Engineering and Safety Center Academy lesson, NASA Document 20200005321, Langley Research Center, Hampton (problem statement slide 18, input deck slides 33 to 44, results slides 48 and 51). |
| Level | Professional |
Problem
A white-painted hollow aluminum box 1 m on a side with walls 2.54 mm thick floats in deep space with a solar flux of 1,371 W/m² on one side (absorptance 0.27, emittance 0.88; aluminum density 2,710 kg/m³, specific heat 910 J/(kg °C), conductivity 204 W/(m °C)). Each wall is one node; walls that share an edge are joined by a conductor; each wall radiates to space; radiation inside the box is ignored. From 20 °C, find the steady-state temperature of each wall and how long the box takes to reach it.
Inputs to Enter
- Six diffusion nodes 100 to 600: capacitance 2,710 × 910 × 1 × 1 × 0.00254 = 6,263.9 J/K, initial temperature 20 °C; heat load 0.27 × 1,371 × 1 = 370.17 W on node 100
- Boundary node 999 (space) at −273.15 °C
- Twelve linear conductors between walls that share an edge: G = 204 × 1 × 0.00254 / 1 = 0.51816 W/K
- Six radiation conductors, each wall to node 999: ε A F = 0.88 × 1 m² (the lesson enters σ ε A = 4.9896 × 10⁻⁸ W/K⁴ with σ = 5.67 × 10⁻⁸)
- Transient to 50,000 s, automatic steps and scheme; target: node 100 at −20 °C
Answers
- Steady state (tool): node 100 −23.24 °C, node 200 −120.88 °C, nodes 300 to 600 −107.94 °C; lesson prints −23.2, −120.9, −107.9 °C
- After 50,000 s (tool): −23.24, −120.86, −107.92 °C; lesson prints the same −23.2, −120.9, −107.9 °C
- With the lesson's σ = 5.67 × 10⁻⁸ the steady values are −23.24, −120.88, −107.93 °C: the rounded constant moves the result by 0.003 °C
- Steady heat balance: 370.17 W absorbed = 370.17 W radiated to space; at 50,000 s 370.25 W leaves and the walls still lose 0.076 W of stored heat
- Sunlit wall: 43.881 W into each of the four side walls by conduction, 194.65 W radiated; each side wall radiates 37.189 W, the far wall 26.837 W
- Transient run: 1,134 Crank-Nicolson steps of 44.09 s (smallest time constant 882.1 s); time-step error estimate 0.0038 °C; node 100 passes −20 °C at 13,211 s
Notes
The tool's default inputs are this box; press Submit. The lesson's temperatures are printed to 0.1 °C and are reproduced at that precision for both the steady state and the 50,000 s transient (test_thermal_network.php, 1,273 checks, which also compares 20 seeded random networks with an independent scipy solution and a set of closed forms). The time for node 100 to pass −20 °C is the tool's value; the lesson shows it only as a chart.