Tools › Structures › Joints › Fastened Repair Doubler › Example

NACA TN 1051 Appendix B: loads carried by the five bolts of a butt joint (0.256, 0.185, 0.159, 0.173 and 0.228 of the joint load)

ToolFastened Repair Doubler
SourceTate, M. B., and Rosenfeld, S. J. (1946). Preliminary Investigation of the Loads Carried by Individual Bolts in Bolted Joints. NACA Technical Note 1051, National Advisory Committee for Aeronautics, Washington, D.C. Appendix B, Numerical Example, pp. 34–36.
LevelProfessional

Problem

A 24S-T plate 5/16 in thick and 2 in wide is spliced by two 3/16 in straps with five 1/4 in steel bolts in line at 1 in pitch (E = 10,500 ksi). The report computes the bolt constant C = 1/437 in/kip (slip = C R / 2) and solves the compatibility equations by hand for the load each bolt carries. Reproduce the distribution with the spring-bar strip of the repair tool: the plate is the skin, the two straps together are the doubler, and one half of the butt joint is the cutout case.

Inputs to Enter

  • Repair: Cutout; Rows per Side 5; Skin Stress 16 ksi (10,000 lb in the 2 in strip); Inner Row Distance 2 in
  • Skin Thickness 0.3125 in, Skin Modulus 10.5 Msi; Doubler Thickness 0.375 in (two 3/16 in straps), Doubler Material: same as the skin
  • Fastener Diameter 0.25 in, Pitch across Load 2 in, Row Spacing 1 in, Edge Distance 0.5 in
  • Flexibility: Entered stiffness, Fastener Stiffness 874,000 lb/in (2 / C: one bolt, both shear planes); Shear Allowable 5,000 lb (does not affect the distribution)
Open the Fastened Repair Doubler tool

Answers

  • Row 1 (where the plate carries the whole load): 25.6 % of the joint load (report: R_1 = 0.256 P; tool 2,556 lb of 10,000 lb)
  • Row 2: 18.5 % (report 0.185 P); row 3: 15.9 % (report 0.159 P)
  • Row 4: 17.2 % (report 0.173 P, three-digit hand arithmetic; the exact solution of the report's equations is 0.1725 P)
  • Row 5: 22.8 % (report 0.228 P); end bolt against the average R_1 / (P / 5) = 1.28 (report 1.28)

Notes

Enter the inputs above and press Submit; read the shares in the load-transfer table. The margins, layout rules and severity factor printed for this case have no counterpart in the report (the allowables are the tool's defaults). Asserted in test_fastened_repair_doubler.php, in the library and through the page.