Tools › Mechanical Design › Acoustics › Construction Noise and Vibration › Example

Five construction machines at 50 ft: Lmax, L10 and noise limit exceedance (FHWA Roadway Construction Noise Model, Figure 19)

ToolConstruction Noise and Vibration
SourceReherman, C. N., Rochat, J. L., Thalheimer, E. S., Lau, M. C., Fleming, G. G., Ferroni, M., and Corbisier, C. (2006). FHWA Roadway Construction Noise Model, Version 1.0 User's Guide. FHWA-HEP-05-054, Federal Highway Administration, Washington, DC. Figure 19 (p. 18), Equations 1 to 3 (p. 20) and Section 5.3 (p. 21).
LevelProfessional

Problem

A ground compactor, a concrete saw, a dozer, a flat bed truck and an excavator work 50 ft from a residential receptor. Their measured maximum levels at 50 ft are 83.2, 89.6, 81.7, 74.3 and 80.7 dBA and their acoustical usage factors 20, 20, 40, 40 and 40 percent. Find the L10 of each machine, the total Lmax and L10, and the exceedance of the daytime limits of 85 dBA (Lmax) and 83 dBA (L10).

Inputs to Enter

  • Assessment: RCNM calculation; Day Criterion 83 (the L10 limit), Lmax Limit 85
  • Five equipment rows set to Custom, each at 50 ft with no shielding: level at 50 ft 83.2 / 89.6 / 81.7 / 74.3 / 80.7 dBA, usage 20 / 20 / 40 / 40 / 40 %
  • Simple mode (L10 = Leq + 3 dBA, the RCNM default adjustment)
Open the Construction Noise and Vibration tool

Answers

  • Compactor: Leq = 83.2 + 10 log 0.20 = 76.2 dBA, L10 = 79.2 dBA (figure: 79.2)
  • Concrete saw L10 85.6, dozer 80.7, flat bed truck 73.3, excavator 79.7 dBA (figure: 85.6, 80.7, 73.3, 79.7)
  • Total Lmax = the loudest machine = 89.6 dBA (figure: 89.6); exceedance of 85 dBA: 4.6 dB (figure: 4.6)
  • Total L10 = 10 log Σ 10^(L10/10) = 88.3 dBA (figure: 88.3); exceedance of 83 dBA: 5.3 dB (figure: 5.3)
  • Against the figure's evening and night limits: L10 limit 80 gives 8.3 dB, L10 limit 74 gives 14.3 dB, Lmax limit 80 gives 9.6 dB (figure: 8.3, 14.3, 9.6)

Notes

Not the tool's default case: enter the rows as listed. The figure is a screenshot of the RCNM program; its measured levels carry one decimal where Table 1 of the guide prints whole decibels, hence the custom rows. Every printed value of the figure is asserted in test_construction_noise_vibration.php, which also compares each built-in equipment row with the text of the guide and of the FTA manual. A screening estimate for one receiver; blasting is not covered.