Tools › Environmental › Health and Safety › Exposure Sampling Statistics › Example

Ten daily dioxane exposures: geometric mean, geometric standard deviation and the probability of noncompliance (NIOSH Sampling Strategy Manual, section 4.4), with one day's consecutive samples (section 4.2.2.1)

ToolExposure Sampling Statistics
SourceLeidel, N. A., Busch, K. A., and Lynch, J. R. (1977). Occupational Exposure Sampling Strategy Manual. DHEW (NIOSH) Publication No. 77-173, National Institute for Occupational Safety and Health, Cincinnati, OH. Section 4.4 (pp. 65–69) and section 4.2.2.1 (pp. 51–53); tolerance factor from U.S. Environmental Protection Agency (2009). Statistical Analysis of Groundwater Monitoring Data at RCRA Facilities: Unified Guidance. EPA 530/R-09-007, Table 17-3.
LevelProfessional

Problem

Charcoal tubes measured a worker's 8-hour time-weighted average exposure to dioxane on ten days over six months; the limit is 100 ppm. Find the long-term geometric mean, the geometric standard deviation and the fraction of days above the limit (the manual's probability of noncompliance). Separately, three consecutive charcoal tubes on one shift measured isoamyl alcohol (limit 100 ppm, method CV_T 0.08): find the time-weighted average and its one-sided 95 % lower and upper confidence limits.

Inputs to Enter

  • Results (ppm): 67, 51, 33, 72, 122, 75, 110, 93, 61, 190; exposure limit 100 ppm
  • Confidence level 95 %, percentile 95th
  • One day's samples (ppm, minutes): 90, 150; 140, 100; 110, 230; CV of method 0.08; action level 0.5 of the limit
Open the Exposure Sampling Statistics tool (loaded with this example)

Answers

  • Geometric mean 78.4 ppm (tool 78.43); geometric standard deviation 1.63 (tool 1.631)
  • z = 0.498, probability of noncompliance 0.309 by the manual's normal table (tool z = 0.497, 31.0 %; the exact value is 0.3097)
  • One day: TWA 110 ppm, TWA / limit 1.10, LCL = 1.10 − 0.08 = 1.02, UCL = 1.18 (tool 1.020 and 1.180)
  • Beyond the manual, tool values: 95th percentile 175.4 ppm; upper tolerance limit (95 %, 95 %) 325.8 ppm with K = 2.911 (Unified Guidance Table 17-3 prints 2.911 for n = 10); 95 % upper confidence limit of the fraction above the limit 52.8 %; Land's exact 95 % upper confidence limit of the mean 126.6 ppm (H = 2.205)

Notes

The tool's default inputs are these two examples of the manual; press Submit. The two examples are separate cases in the manual (different substances, both with a 100 ppm limit). The manual gives no confidence limit for the probability of noncompliance and no tolerance limit: those tool values are checked in test_exposure_statistics.php against an independent numerical computation and, for K and Land's factor, against the tables of the EPA Unified Guidance. The page describes the data; it does not decide compliance.