Tools › Environmental › Groundwater › Groundwater Plume Transport › Example

Dissolved BTEX plume at a fuel site: centerline concentrations by the Domenico solution with no decay, first-order decay and instantaneous reaction (BIOSCREEN manual, Hill AFB)

ToolGroundwater Plume Transport
SourceNewell, C. J., McLeod, R. K., and Gonzales, J. R. (1996). BIOSCREEN Natural Attenuation Decision Support System, User's Manual, Version 1.3. EPA/600/R-96/087, U.S. Environmental Protection Agency, Office of Research and Development, Washington, DC. Appendix A.6, Example 2 (UST Site 870, Hill AFB, Utah): input screen Figure 6, p. 62, and centerline output Figure 7, p. 63; model equations in Appendix A.1 and the Version 1.4 revisions, p. 9.
LevelProfessional

Problem

At a fuel release site the groundwater moves at a seepage velocity of 1,609.1 ft/yr. The source is a vertical plane 10 ft thick with a center zone 100 ft wide at 9 mg/L total BTEX, flanked on each side by 25 ft at 2.8 mg/L and 50 ft at 0.07 mg/L. Find the concentration along the plume centerline after 5 years, at 145-ft steps to 1,450 ft, with no decay, with first-order decay at a solute half-life of 0.10 year, and with the instantaneous-reaction model for the electron acceptors measured at the site.

Inputs to Enter

  • Seepage velocity 1,609.1 ft/yr (entered); effective porosity 0.25; retardation from bulk density 1.7 kg/L, Koc 38 L/kg, foc 0.0008 → R = 1.207
  • Dispersivities from the plume length 1,450 ft by the Xu and Eckstein relation: α_x = 28.50 ft, α_y = 0.10 α_x = 2.850 ft, α_z = 0
  • Solute half-life 0.10 yr (λ = 6.93 per year), decay in the dissolved and sorbed phases; one-term (BIOSCREEN) longitudinal factor
  • Electron acceptors: oxygen used 5.78, nitrate used 17, ferrous iron 11.3, sulfate used 100, methane 0.414 mg/L → biodegradation capacity 27.64 mg/L
  • Source: three concentrations, zone widths 100 / 25 / 25 / 50 / 50 ft, thickness 10 ft, constant; time 5 yr; profile length 1,450 ft; receptor at 1,015 ft; standard 0.005 mg/L
Open the Groundwater Plume Transport tool (loaded with this example)

Answers

  • No decay at 145, 290, ... 1,450 ft (mg/L): 8.467, 7.466, 6.684, 6.089, 5.624, 5.250, 4.940, 4.679, 4.455, 4.260 (tool and manual, every printed digit)
  • First-order decay: 4.348, 1.969, 0.905, 0.424, 0.201, 0.096, 0.047, 0.023, 0.011, 0.005 (tool and manual)
  • Instantaneous reaction: 8.466, 7.407, 6.350, 5.268, 4.192, 3.152, 2.168, 1.245, 0.385, 0.000 (tool and manual)
  • Tool only (no printed counterpart): at the 1,015-ft receptor the 0.005 mg/L standard is reached after 0.372 yr (no decay), 0.465 yr (first-order) and 1.07 yr (instantaneous reaction); plume length to the standard 1,467 ft with first-order decay and 1,373 ft with the instantaneous reaction, both at steady state by 5 years

Notes

The tool's default inputs are this case; press Submit. The printed values are reproduced only with the retardation factor computed from the bulk density, Koc and foc of the input screen (1.207; the screen displays 1.2) and with the dispersivity relation evaluated with 3.28 ft per meter as the manual prints it (test_plume_transport.php). The manual's table of inputs gives a conductivity of 8.05 × 10⁻³ cm/s, but its input screen shows 8.1E-03 and the velocity 1,609.1 ft/yr that follows from it. The manual's field data (9, 8, 1, 0.02 and 0.005 mg/L at 0, 290, 1,015, 1,305 and 1,450 ft) are plotted for comparison; the Domenico solution is an approximation and the result is a screening estimate.