Tools › Civil and Geotechnical › Foundations › MSE Wall Design › Example

A 30 ft MSE wall with steel strips under a traffic surcharge: sliding, eccentricity, bearing, tension and pullout in every layer (FHWA GEC 11, 2023, Example C1)

ToolMSE Wall Design
SourceTaylor, T. P., Collin, J. G., Boyle, S., Fishman, K., and Han, J. (2023). Design and Construction of Mechanically Stabilized Earth (MSE) Walls. Report FHWA-HIF-24-002, FHWA GEC 011, Federal Highway Administration, Washington, DC. Appendix C, Example C1, pp. C-2 to C-43.
LevelProfessional

Problem

A segmental precast panel wall has a design height of 30 ft, a level backfill and a traffic surcharge equal to 2 ft of soil. The reinforced fill has φ′ = 34° and 125 pcf, the retained fill and the foundation soil φ′ = 30° and 120 pcf. The reinforcement is 2 in by 5/32 in galvanized steel strips of 60 ksi steel, 21 ft long (0.7 H), in twelve layers on 5 ft panels. Check sliding, limiting eccentricity and bearing at the Strength I limit state with the earth thrust inclined at two-thirds of the friction angle, and find by the simplified method the maximum tension, the number of strips, the rupture ratio and the pullout ratio of every layer for a 75-year design life.

Inputs to Enter

  • H = 30 ft, L = 21 ft, level backfill, traffic surcharge 250 psf (2 ft × 125 pcf) over the reinforced zone and the retained fill
  • Reinforced fill 125 pcf, 34°; retained fill 120 pcf, 30°; foundation 120 pcf, 30° (the page computes the bearing resistance; the example leaves it open)
  • Steel strips, simplified method; layers at 2.25, 3.75, 6.25, 8.75, 11.25, 13.75, 16.25, 18.75, 21.25, 23.75, 26.25 and 28.75 ft; strips per 5 ft panel 2 in layers 1 to 9 and 3 in layers 10 to 12 (the example's result)
  • Strip 2 in × 0.15625 in, F_y 60 ksi, design life 75 years, zinc coating 3.4 mils, corrosion rates 0.58, 0.16 and 0.47 mil per year; F* 2.0 at the surface falling to tan 34° at 20 ft
  • Load factors EV 1.35 / 1.00, EH 1.50, LS 1.75; resistance factors sliding 1.0, bearing 0.65, strips 0.75, pullout 0.90 (the manual's printed values, the page's defaults)
Open the MSE Wall Design tool (loaded with this example)

Answers

  • K_ab = 0.297 with δ = 20°; nominal forces V_1 = 78.75, F_1H = 15.09, F_1V = 5.49, F_2H = 2.10, F_2V = 0.76 kip/ft (book: the same)
  • Sliding, critical case: 50.99 kip/ft against 26.30 kip/ft, CDR 1.94, margin +0.94 (book 50.99 and 1.94)
  • Limiting eccentricity, critical case: e = 2.05 ft, e / L = 0.10 (book 2.05 ft, 0.10), against L / 4 = 5.25 ft
  • Bearing: maximum ΣV = 125.07 kip/ft, e = 1.45 ft, L′ = 18.11 ft, 6.91 ksf; critical 5.64 ksf; Service I 4.90 ksf (book: the same); computed q_R = 15.82 ksf, CDR 2.29 (not in the book)
  • Strip after 75 years: zinc gone in 16.0 years, loss 0.055 in, factored strength 9.07 kips per strip (book 16.00 yr, 0.055 in, 9.07 kip)
  • T_max, layers 1 to 12: 1.00, 0.88, 1.52, 1.90, 2.24, 2.55, 2.82, 3.05, 3.33, 3.69, 4.04, 4.40 kip/ft (book: the same)
  • Rupture CDR: 3.63, 4.12, 2.39, 1.91, 1.62, 1.42, 1.29, 1.19, 1.09, 1.48, 1.35, 1.24 (book: the same); lowest margin +0.09 in layer 9
  • Tension for pullout, without the live load: 0.53, 0.57, 1.15, 1.55, 1.90, 2.22, 2.51, 2.75, 3.04, 3.40, 3.76, 4.11 kip/ft; pullout CDR 1.42, 2.06, 1.55, 1.45, 1.33, 1.21, 1.14, 1.10, 1.11, 1.83, 1.99, 2.15 (book: the same); lowest margin +0.10 in layer 8
  • Least reinforcement length 21.00 ft, set by the minimum 0.7 H; sliding needs 9.59 ft, the eccentricity limit 13.91 ft, bearing 14.91 ft and pullout 19.68 ft (not in the book)

Notes

The tool's default inputs are this wall; press Submit. Choose the coherent gravity method under Internal Stability for the example's second set of numbers (the page follows Equation 71 of the manual, with the EH factor on the vertical part of the thrust, where the example uses the EV factor: tensions up to 0.6 percent higher than the book's), or Geogrid with the stiffness method for its geosynthetic part. Every book value quoted here, the coherent gravity and stiffness-method values of the example, and Example C2 of the same appendix (infinite backslope) are asserted in test_mse_wall.php. This entry replaces the earlier one on Example E4 of the 2009 edition of the manual, whose rules remain available in Advanced mode. The page does not check overall stability, settlement or the facing.