Tools › Civil and Geotechnical › Foundations › Drilled Shaft Capacity › Example

A 5 ft by 60 ft drilled shaft through silty sand into stiff clay: side and base resistance, strength check and settlement (FHWA GEC 10, Illustrative Examples 10-1 to 10-6)

ToolDrilled Shaft Capacity
SourceBrown, D. A., Turner, J. P., Castelli, R. J., and Loehr, E. J. (2018). Drilled Shafts: Construction Procedures and Design Methods. Geotechnical Engineering Circular No. 10, FHWA-NHI-18-024, Federal Highway Administration, Washington, DC. Illustrative Examples 10-1 (pp. 10-12 to 10-14), 10-2 (p. 10-18), 10-3 (p. 10-20), 10-5 (p. 10-29) and 10-6 (pp. 10-33 to 10-35).
LevelProfessional

Problem

A drilled shaft 5 ft in diameter and 60 ft deep passes through 15 ft of silty sand above the groundwater level (N_60 = 9, 115 pcf), 18 ft of silty sand below it (N_60 = 27, 125 pcf) and 27 ft of stiff clay (s_u = 2,000 psf from UU triaxial tests, 125 pcf). Find the nominal side resistance of each layer by the β-method and the α-method, the nominal base resistance, the sum of factored resistances against a Strength I demand of 766 kips, and the settlement under a Service I load of 575 kips.

Inputs to Enter

  • Diameter 5 ft, tip depth 60 ft, groundwater at 15 ft
  • Layer 1: silty sand, 15 ft, 115 pcf, N_60 9, φ′ 38°; layer 2: silty sand, 18 ft, 125 pcf, N_60 27, φ′ 41° (the friction angles as the manual rounds them)
  • Layer 3: clay, UU strength 2,000 psf, 125 pcf
  • Factored compression 766 kip, service load 575 kip, tolerable settlement 1.5 in; resistance factors 0.55 (side, cohesionless), 0.45 (side, cohesive), 0.40 (base, cohesive)
Open the Drilled Shaft Capacity tool (loaded with this example)

Answers

  • Layer 1: σ′_v 862.5 psf, σ′_p 5,768 psf, OCR 6.7, K_o 1.24, β 0.97, R_SN 197.2 kips in the manual (tool 196.6 kip with β 0.967)
  • Layer 2: σ′_v 2,288.4 psf, σ′_p 13,890 psf, OCR 6.1, β 0.98, R_SN 635.6 kips in the manual (tool 631.5 kip with β 0.976)
  • Layer 3: s_u(CIUC) = 2,000 / 0.778 = 2,571 psf, α = 0.44, f_SN 1,131 psf, R_SN 479.7 kips (tool 479.7 kip)
  • Base: q_BN = 9.0 × 2,571 = 23,139 psf, R_BN 453.6 kips in the manual (tool 454.4 kip)
  • Sum of factored resistances 855.4 kips against 766 kips, capacity to demand 1.12 (tool 853.1 kip, margin +0.11)
  • Service: shaft weight 121.6 kips, failure threshold 1,766.1 kips (tool 1,762.2 kip), axial force 39 % of it, settlement 0.19 inch (tool 0.19 in)
  • Tolerable settlement 1.5 inch = 2.5 % of the diameter: 93 % of the threshold on the cohesive curve of Figure 10-10 (tool 93.0 %), R_service = 0.93 × 1,766.1 − 121.6 = 1,521 kips against 575 kips (tool 1,517.2 kip, margin +1.64)

Notes

The tool's default inputs are this shaft; press Submit. The tool carries β to full precision where the manual multiplies the two-digit value, which is the whole of the 0.3 % difference in the factored sum; the manual's text for layer 2 prints "(1.08)" where β is 0.98. The manual's larger example, Appendix A Table A-5 (8 ft shaft, tip at 201 ft, eight layers), is reproduced to the printed pound in every cohesionless layer and at the base in test_drilled_shaft.php. The settlement and the load at the tolerable settlement come from the manual's Figure 10-10, whose curves were read from the vector drawing in the manual's file to about ± 0.5 % of the failure threshold.