| Source | Illustrative case. Ring and skin shear flow as in Niles, A. S., and Newell, J. S. (1943). Airplane Structures, 3rd ed., Vol. I. John Wiley and Sons, New York. Arts. 17:6 to 17:8; frame model by the direct stiffness method, McGuire, W., Gallagher, R. H., and Ziemian, R. D. (2000). Matrix Structural Analysis, 2nd ed. John Wiley and Sons, New York. |
| Level | Professional |
Problem
A circular fuselage frame (shear-tied to a skin of 42 in inner radius, centroid 2 in inside its outer cap) carries a floor beam 15 in below its center, pinned to the frame at both ends and propped by two pin-ended struts that run from the beam at x = ±12 in to the frame at 250° and 290°. Four seat tracks at x = −20, −8, 8 and 20 in each put 900 lb downward on the floor beam. The total load is reacted by the skin shear flow. Find the loads in the frame, the floor beam and the struts. A closed ring with a floor beam and struts is beyond the closed-form coefficients, so the finite element model is used.
Inputs to Enter
- Advanced mode; Skin Inner Radius 42 in; Frame Attachment: shear-tied (outer cap on the skin); Frame Area 0.60 in², Frame Inertia 2.0 in⁴, Centroid to Outer Frame 2 in, Frame Modulus 10.5 Msi, Skin Thickness 0.040 in (ring radius 40 in); reinforcement checks off, so the frame depth and cap thicknesses are not asked
- Method: finite element, 72 ring elements; floor beam pinned to the ring, height y = −15 in, area 0.80 in², inertia 6.0 in⁴
- Struts (x on floor, ring angle, area): −12 250 0.2 and 12 290 0.2
- Loads located on the floor beam: Track 1 to Track 4 at x = −20, −8, 8, 20 in, V = −900 lb each
Answers
- Resultant 3,600 lb downward; balancing skin shear flow peaks at 28.63 lb/in at the sides
- Frame: largest bending moment 4,482.1 lb-in at the floor-beam attachment (337.98°), largest normal force 2,004.6 lb at 240°, largest shear 792.38 lb at the strut attachment (250°)
- Frame at 0°, 90° and 270°: M = −1,821.1, 2,607.4 and −154.65 lb-in; N = 900.02, −353.73 and 1,764.1 lb; no shear at the crown and keel (symmetric loading)
- Floor beam: 6,164.1 lb-in under the outer tracks, 5,451.2 lb-in between the inner tracks, axial compression 1,303.4 lb outboard of the struts and 1,410.5 lb between them
- Each strut carries 1,443.1 lb in compression; vertical diameter lengthens 0.09024 in, horizontal diameter shortens 0.05873 in
- Checks: equilibrium residual and the three restraint reactions of the model are zero to round-off
Notes
Enter the inputs above and press Submit; the values are asserted by test_ring_frame_analysis_page.php, and a similar floor-beam case with a strut agrees with the independent numpy model References/Ring-Frame/ring_check.py to four digits. The loads and member sizes are invented for illustration. The floor beam is assumed not to change the skin shear flow, and the model's elements stretch as well as bend, so results differ slightly from the inextensible closed-form ring.
More Examples for This Tool
- Fuselage ring frame under four floor and seat loads: moment, normal force and shear by the Wise coefficients (Niles and Newell Example 17:8)
- Ring pinched by two opposite radial loads: bending moments and changes of diameter against the classical closed forms
- Crown frame under an added antenna side load: added moment, shear and normal force, and doublers sized to carry all of it
- Doubler over part of a ring frame: how the added stiffness draws bending moment to the reinforced arc (finite-segment summation)
- Elliptic ring 25 × 14.7 in under four balanced 2,000 lb loads: thrust, shear and moment against Burke's working charts (NACA TN 444)
- Elliptical fuselage frame 96 × 76 in under floor loads reacted by skin shear flow: internal loads by summation and doublers for the added load
- Floating frame standing 1 in off the skin: ring radius, shear flow at the skin line, shear clips and doublers under floor loads