Tools › Structures › Frames and Trusses › Ring Frame Analysis › Example
Floating frame standing 1 in off the skin: ring radius, shear flow at the skin line, shear clips and doublers under floor loads
| Tool | Ring Frame Analysis |
| Source | Illustrative case. Loads of Niles, A. S., and Newell, J. S. (1943). Airplane Structures, 3rd ed., Vol. I. John Wiley and Sons, New York. Art. 17:8; shear flow at a radius different from the frame's neutral fiber as in Fahlbusch, H., and Wegner, W. (1941). Stress Analysis of Circular Frames. NACA Technical Memorandum 999, eq. (1) to (12). |
| Level | Professional |
Problem
A floating frame stands 1 in inside a skin of 42 in inner radius: the stringers pass through the gap and the frame is tied to the skin only by shear clips. Its centroid is 2 in inside its own outer cap. It carries the four floor and seat loads of Niles and Newell's example (1,020, 1,440, 935 and 675 lb down at x = −28.5, −0.5, 21.5 and 29.25 in), entered as added limit loads. Find the ring radius and the added internal loads with the skin shear flow acting where the skin is, 3 in outboard of the frame's centroid, and check the default doublers and shear clips spaced 4 in with two fasteners each.
Inputs to Enter
- Advanced mode; Skin Inner Radius 42 in; Frame Attachment: floating (shear clips); Gap to Inner Skin 1.0 in; Frame Area 0.60 in², Frame Inertia 2.0 in⁴, Centroid to Outer Frame 2 in, Frame Modulus 10.5 Msi, Skin Thickness 0.040 in
- Frame Depth 4.5 in, Outer Cap Thickness 0.050 in, Inner Cap Thickness 0.050 in; Shear Flow Acts: on the skin line (correction)
- Default loads B, C, D, E by x on the lower half; reinforcement: additional load, limit loads, default doublers inside the C over the whole ring
- Frame to Skin Attachment: Pitch or Clip Spacing 4 in, allowable computed, Fasteners per Clip 2
Answers
- Ring radius R = R_s − g_sk − y_f = 42 − 1 − 2 = 39 in (40 in for the same frame shear-tied); effective skin is not available for a floating frame; the same x positions now fall at 223.05°, 269.27°, …
- Skin shear flow at the skin mid-thickness, radius 42.02 in, 3.02 in outboard of the ring axis; it peaks at 31.74 lb/in
- At the section at 0°: M = −11,084 lb-in, N = +1,097.4 lb, S = +193.73 lb, of which 103.27 lb is the skin-line correction; the correction adds no bending moment
- Largest moment 14,790 lb-in at 269.27° (15,463 lb-in shear-tied), largest normal force 1,755.9 lb and shear −899.71 lb at 318.59°; diameter changes +0.5013 and −0.5018 in
- Doublers stay on the frame's caps: y_o = 0.050 + 0.125/2 = 0.1125 in, y_i = 4.5 − 0.050 − 0.125/2 = 4.388 in, arm 4.275 in
- Margins: outer cap tension 64.00/35.41 − 1 = +0.81; inner cap compression 39.00/24.59 − 1 = +0.59; web shear buckling 9.971/6.314 − 1 = +0.58 (lowest); cap fastener 595.7/236.8 − 1 = +1.52
- Shear clips: 31.74 lb/in × 4 in × 1.5 = 190.4 lb per clip against 2 × 595.7 = 1,191 lb, margin +5.26
Notes
Enter the inputs above and press Submit; the values are asserted by test_ring_frame_analysis_page.php. The skin-line correction with the shear flow at one radius and the ring at another reproduces NACA TM 999 in the library test. A floating frame receives the skin shear at its clips, not continuously; the tool keeps the continuous shear flow of the book for the internal loads and uses the clip spacing only for the clip check. The loads are the book's; the frame, gap, doublers and clips are invented for illustration, and the margins say nothing about the existing frame under its own baseline loads.
More Examples for This Tool
- Fuselage ring frame under four floor and seat loads: moment, normal force and shear by the Wise coefficients (Niles and Newell Example 17:8)
- Ring pinched by two opposite radial loads: bending moments and changes of diameter against the classical closed forms
- Crown frame under an added antenna side load: added moment, shear and normal force, and doublers sized to carry all of it
- Fuselage frame with a floor beam and two struts under seat-track loads: ring, floor-beam and strut loads by the finite element model
- Doubler over part of a ring frame: how the added stiffness draws bending moment to the reinforced arc (finite-segment summation)
- Elliptic ring 25 × 14.7 in under four balanced 2,000 lb loads: thrust, shear and moment against Burke's working charts (NACA TN 444)
- Elliptical fuselage frame 96 × 76 in under floor loads reacted by skin shear flow: internal loads by summation and doublers for the added load