Tools › Materials › Aluminum › 2219-T62 Sheet and plate

2219-T62 Sheet and plate: MIL-HDBK-5J Design Allowables

Material classAluminum
Alloy / temper / form2219 / T62 / Sheet and plate
SpecificationsAMS 4031 & AMS-QQ-A-250/30
HandbookMIL-HDBK-5J, 31 January 2003, section 3.2.8.0, Table 3.2.8.0(b) (pdf page 168 of the chapter file)
Dimension bands1
Density2851 kg/m³

Design Mechanical and Physical Properties (room temperature)

Converted from the handbook table (ksi, Msi, lb/in³) and rounded to 4 significant figures; dimension bands in inches with mm in parentheses. Bases: A and B are statistical minimums (99 % and 90 % probability at 95 % confidence), S the specification minimum. Grain directions: L longitudinal, LT long transverse, ST short transverse.

Dimension band0.020–2.000 in (0.508–50.8 mm)
SpecificationAMS 4031 & AMS-QQ-A-250/30
BasisAB
Ftu, MPaL372.3379.2
LT372.3379.2
Fty, MPaL248.2255.1
LT248.2255.1
Fcy, MPaL255.1268.9
LT255.1262
Fsu, MPaL213.7220.6
LT213.7220.6
Fbru (e/D = 1.5), MPaL579.2586.1
LT579.2586.1
Fbru (e/D = 2.0), MPaL737.7751.5
LT737.7751.5
Fbry (e/D = 1.5), MPaL427.5441.3
LT427.5441.3
Fbry (e/D = 2.0), MPaL544.7558.5
LT544.7558.5
E, GPa72.3972.39
Ec, GPa74.4674.46
G, GPa27.5827.58
ν0.330.33
ρ, kg/m³28512851

Effect of Temperature

Percent of the room-temperature value against temperature, digitized from the handbook figures (the shortest exposure of each figure, every 10 °F). Strength curves give the allowable at temperature; "after exposure" curves give the room-temperature property after a soak at that temperature.

Strength allowables at temperature, percent of room temperature

°CF_tuF_ty
-184119.7116.3
-129109.3108.4
-73104.9104.6
-18102.5102
38100.398.8
9394.693.7
14981.383.8
20463.867.3
2645.750.7
31631.636.9
37119.222.2
4277.89.1

Factors in percent of the room-temperature allowable.

Other 2219 Tables

Source and Use

U.S. Department of Defense (2003). Metallic Materials and Elements for Aerospace Vehicle Structures. MIL-HDBK-5J, 31 January 2003 (public domain). The values are the handbook's design allowables as extracted from the chapter tables; check the printed table before use in a certified analysis, and note that MIL-HDBK-5J was superseded by MMPDS, whose later editions may differ. No warranty is given.