Tools › Materials › Steel › Custom 455-H950 Bar

Custom 455-H950 Bar: MIL-HDBK-5J Design Allowables

Material classSteel
Alloy / temper / formCustom 455 / H950 / Bar
SpecificationsAMS 5617
HandbookMIL-HDBK-5J, 31 January 2003, section 2.6.4.0, Table 2.6.4.0(b) (pdf page 141 of the chapter file)
Dimension bands2
Density775 kg/m³

Design Mechanical and Physical Properties (room temperature)

Converted from the handbook table (ksi, Msi, lb/in³) and rounded to 4 significant figures; dimension bands in inches with mm in parentheses. Bases: A and B are statistical minimums (99 % and 90 % probability at 95 % confidence), S the specification minimum. Grain directions: L longitudinal, LT long transverse, ST short transverse.

Dimension band0–4 in (0–101.6 mm)4.001–6.000 in (101.6–152.4 mm)
SpecificationAMS 5617AMS 5617
BasisSS
Ftu, MPaL15511517
LT15171517
ST15171517
Fty, MPaL14481413
LT14131413
ST14131413
Fcy, MPaL15101475
LT15101475
ST15101475
Fsu, MPaL917896.3
LT917896.3
ST917896.3
Fbru (e/D = 1.5), MPaL24482392
LT24482392
ST24482392
Fbru (e/D = 2.0), MPaL31033034
LT31033034
ST31033034
Fbry (e/D = 1.5), MPaL21442089
LT21442089
ST21442089
Fbry (e/D = 2.0), MPaL25232468
LT25232468
ST25232468
e, %L1010
LT55
ST55
E, GPa196.5196.5
Ec, GPa206.8206.8
G, GPa77.9177.91
ν0.270.27
ρ, kg/m³77507750

Effect of Temperature

Percent of the room-temperature value against temperature, digitized from the handbook figures (the shortest exposure of each figure, every 10 °F). Strength curves give the allowable at temperature; "after exposure" curves give the room-temperature property after a soak at that temperature.

Strength allowables at temperature, percent of room temperature

Elongation and exposure effects

°CF_tuF_tyF_su
-73109.5106.3
-18103.4103.4102.2
38999997.7
9394.394.392.5
14989.889.887.3
20486.784.583.4
2683.38079.8
31680.275.976.2
37176.572.172.2

Factors in percent of the room-temperature allowable.

Other Custom 455 Tables

Source and Use

U.S. Department of Defense (2003). Metallic Materials and Elements for Aerospace Vehicle Structures. MIL-HDBK-5J, 31 January 2003 (public domain). The values are the handbook's design allowables as extracted from the chapter tables; check the printed table before use in a certified analysis, and note that MIL-HDBK-5J was superseded by MMPDS, whose later editions may differ. No warranty is given.