Tools › Materials › Steel › 17-4PH-H900 Bar

17-4PH-H900 Bar: MIL-HDBK-5J Design Allowables

Material classSteel
Alloy / temper / form17-4PH / H900 / Bar
SpecificationsAMS 5643
HandbookMIL-HDBK-5J, 31 January 2003, section 2.6.9.0, Table 2.6.9.0(e) (pdf page 199 of the chapter file)
Dimension bands1
Density0.282 lb/in3

Design Mechanical and Physical Properties (room temperature)

As printed in the handbook table. Bases: A and B are statistical minimums (99 % and 90 % probability at 95 % confidence), S the specification minimum. Grain directions: L longitudinal, LT long transverse, ST short transverse.

Dimension band0–8 in
SpecificationAMS 5643
BasisAB
Ftu, ksiL190195
Fty, ksiL170175
Fcy, ksiL170175
Fsu, ksiL123126
Fbru (e/D = 1.5), ksiL313322
Fbru (e/D = 2.0), ksiL380390
Fbry (e/D = 1.5), ksiL255262
Fbry (e/D = 2.0), ksiL280288
e, %L1010
E, Msi28.528.5
Ec, Msi3030
G, Msi11.211.2
ν0.270.27
ρ, lb/in30.2820.282

Effect of Temperature

Percent of the room-temperature value against temperature, digitized from the handbook figures (the shortest exposure of each figure, every 10 °F). Strength curves give the allowable at temperature; "after exposure" curves give the room-temperature property after a soak at that temperature.

Strength allowables at temperature, percent of room temperature

Moduli at temperature

°FF_tuF_tyF_cyF_suF_bruF_bry
10099.598.698.999.298.899.7
20095.194.193.79594.995.3
30091.990.588.190.890.591.2
400898782.286.28687.1
50085.983.576.581.281.282.5
60083.980.670.376.175.977.7
70081.77863.670.269.872.3
80078.174.356.463.963.266.5
100060.154.33948.347.9

Factors in percent of the room-temperature allowable.

Other 17-4PH Tables

Source and Use

U.S. Department of Defense (2003). Metallic Materials and Elements for Aerospace Vehicle Structures. MIL-HDBK-5J, 31 January 2003 (public domain). The values are the handbook's design allowables as extracted from the chapter tables; check the printed table before use in a certified analysis, and note that MIL-HDBK-5J was superseded by MMPDS, whose later editions may differ. No warranty is given.