Tools › Materials › Steel › 9Ni-4Co-0.30C-Quenched and tempered Sheet, strip, and plate

9Ni-4Co-0.30C-Quenched and tempered Sheet, strip, and plate: MIL-HDBK-5J Design Allowables

Material classSteel
Alloy / temper / form9Ni-4Co-0.30C / Quenched and tempered / Sheet, strip, and plate
SpecificationsAMS 6524
HandbookMIL-HDBK-5J, 31 January 2003, section 2.4.3.0, Table 2.4.3.0(b) (pdf page 80 of the chapter file)
Dimension bands2
Density775 kg/m³

Design Mechanical and Physical Properties (room temperature)

Converted from the handbook table (ksi, Msi, lb/in³) and rounded to 4 significant figures; dimension bands in inches with mm in parentheses. Bases: A and B are statistical minimums (99 % and 90 % probability at 95 % confidence), S the specification minimum. Grain directions: L longitudinal, LT long transverse, ST short transverse.

Dimension band0.000–0.249 in (0–6.325 mm)0.000–0.250 in (0–6.35 mm)
SpecificationAMS 6524AMS 6524
BasisSS
Ftu, MPaLT15171517
Fty, MPaLT12761310
Fcy, MPaLT…1441
Fsu, MPaLT…944.6
Fbru (e/D = 1.5), MPaLT…2386
Fbru (e/D = 2.0), MPaLT…3034
Fbry (e/D = 1.5), MPaLT…2006
Fbry (e/D = 2.0), MPaLT…2220
e, %LT610
E, GPa196.5196.5
Ec, GPa205.5205.5
ρ, kg/m³77507750

Effect of Temperature

Percent of the room-temperature value against temperature, digitized from the handbook figures (the shortest exposure of each figure, every 10 °F). Strength curves give the allowable at temperature; "after exposure" curves give the room-temperature property after a soak at that temperature.

Strength allowables at temperature, percent of room temperature

Moduli at temperature

°CF_tuF_tyF_cyF_suF_bruF_bry
-73105.8107.4
-18102.4103102.5101.6101.2101.3
3898.698.798.398.298.598.8
9395.494.894.795.495.996.4
14992.891.490.992.893.694.6
20491.289.187.590.391.393.3
2684.687.688.892.7

Factors in percent of the room-temperature allowable.

Other 9Ni-4Co-0.30C Tables

Source and Use

U.S. Department of Defense (2003). Metallic Materials and Elements for Aerospace Vehicle Structures. MIL-HDBK-5J, 31 January 2003 (public domain). The values are the handbook's design allowables as extracted from the chapter tables; check the printed table before use in a certified analysis, and note that MIL-HDBK-5J was superseded by MMPDS, whose later editions may differ. No warranty is given.