Tools › Materials › Steel › 250 Maraging-Maraged at 900 F Sheet

250 Maraging-Maraged at 900 F Sheet: MIL-HDBK-5J Design Allowables

Material classSteel
Alloy / temper / form250 Maraging / Maraged at 900 F / Sheet
SpecificationsAMS 6520
HandbookMIL-HDBK-5J, 31 January 2003, section 2.5.1.0, Table 2.5.1.0(b) (pdf page 94 of the chapter file)
Dimension bands1
Density7916 kg/m³

Design Mechanical and Physical Properties (room temperature)

Converted from the handbook table (ksi, Msi, lb/in³) and rounded to 4 significant figures; dimension bands in inches with mm in parentheses. Bases: A and B are statistical minimums (99 % and 90 % probability at 95 % confidence), S the specification minimum. Grain directions: L longitudinal, LT long transverse, ST short transverse.

Dimension band0.000–0.187 in (0–4.75 mm)
SpecificationAMS 6520
BasisS
Ftu, MPaL1703
LT1758
Fty, MPaL1641
LT1689
Fcy, MPaL1524
LT1551
Fsu, MPaL1020
LT1020
Fbru (e/D = 1.5), MPaL2255
LT2255
Fbru (e/D = 2.0), MPaL3061
LT3061
Fbry (e/D = 1.5), MPaL1917
LT1917
Fbry (e/D = 2.0), MPaL2434
LT2434
e, %L…
LT4
ν0.31
ρ, kg/m³7916

Effect of Temperature

Percent of the room-temperature value against temperature, digitized from the handbook figures (the shortest exposure of each figure, every 10 °F). Strength curves give the allowable at temperature; "after exposure" curves give the room-temperature property after a soak at that temperature.

Strength allowables at temperature, percent of room temperature

Moduli at temperature

°CF_tuF_tyF_cyF_suF_bruF_bry
-184118.6118
-129112.7109.6
-73107.7105.3
-18103101.8
3898.899.398.499.299.899.1
939495.892.594.997.295
14990.492.688.490.894.992
20487.689.385.486.492.488.9
2686.486.383.282.289.686.2
31685.483.381.778.486.883.5
37183.479.979.476.58379.6
42778.977.175.876.177.474.2
53861.153.2

Factors in percent of the room-temperature allowable.

Other 250 Maraging Tables

Source and Use

U.S. Department of Defense (2003). Metallic Materials and Elements for Aerospace Vehicle Structures. MIL-HDBK-5J, 31 January 2003 (public domain). The values are the handbook's design allowables as extracted from the chapter tables; check the printed table before use in a certified analysis, and note that MIL-HDBK-5J was superseded by MMPDS, whose later editions may differ. No warranty is given.