Tools › Materials › Heat-Resistant › A-286-Solution treated and aged Sheet, strip, / and plate

A-286-Solution treated and aged Sheet, strip, / and plate: MIL-HDBK-5J Design Allowables

Material classHeat-Resistant
Alloy / temper / formA-286 / Solution treated and aged / Sheet, strip, / and plate
SpecificationsAMS 5525
HandbookMIL-HDBK-5J, 31 January 2003, section 6.2.1.0, Table 6.2.1.0(b) (pdf page 6 of the chapter file)
Dimension bands1
Density0.287 lb/in3

Design Mechanical and Physical Properties (room temperature)

As printed in the handbook table. Bases: A and B are statistical minimums (99 % and 90 % probability at 95 % confidence), S the specification minimum. Grain directions: L longitudinal, LT long transverse, ST short transverse.

Dimension band0.004– in
SpecificationAMS 5525
BasisS
Ftu, ksiLT140
Fty, ksiLT95
Fcy, ksiLT95
Fsu, ksiLT91
Fbru (e/D = 1.5), ksiLT210
Fbru (e/D = 2.0), ksiLT266
Fbry (e/D = 1.5), ksiLT142
Fbry (e/D = 2.0), ksiLT171
e, %LT15
E, Msi29.1
Ec, Msi29.1
G, Msi11.1
ν0.31
ρ, lb/in30.287

Effect of Temperature

Percent of the room-temperature value against temperature, digitized from the handbook figures (the shortest exposure of each figure, every 10 °F). Strength curves give the allowable at temperature; "after exposure" curves give the room-temperature property after a soak at that temperature.

Strength allowables at temperature, percent of room temperature

Moduli at temperature

°FF_tuF_tyF_bruF_bry
-300124.8112.5
-200115.8107.1
-100108.7103.7
0101.6101.6
10098.498.498.598.5
20096.196.194.994.9
30093.893.889.992.5
40091.591.586.690.5
50089.589.584.689.9
600888884.489.4
70087.687.68488.2
80086.592.383.587.2
100082.480.580.5
120067.567.5

Factors in percent of the room-temperature allowable.

Other A-286 Tables

Source and Use

U.S. Department of Defense (2003). Metallic Materials and Elements for Aerospace Vehicle Structures. MIL-HDBK-5J, 31 January 2003 (public domain). The values are the handbook's design allowables as extracted from the chapter tables; check the printed table before use in a certified analysis, and note that MIL-HDBK-5J was superseded by MMPDS, whose later editions may differ. No warranty is given.