Tools › Materials › Aluminum › 7049-T7351 Plate

7049-T7351 Plate: MIL-HDBK-5J Design Allowables

Material classAluminum
Alloy / temper / form7049 / T7351 / Plate
SpecificationsAMS 4200
HandbookMIL-HDBK-5J, 31 January 2003, section 3.7.3.0, Table 3.7.3.0(b) (pdf page 306 of the chapter file)
Dimension bands8
Density2851 kg/m³

Design Mechanical and Physical Properties (room temperature)

Converted from the handbook table (ksi, Msi, lb/in³) and rounded to 4 significant figures; dimension bands in inches with mm in parentheses. Bases: A and B are statistical minimums (99 % and 90 % probability at 95 % confidence), S the specification minimum. Grain directions: L longitudinal, LT long transverse, ST short transverse.

Dimension band0.750–1.000 in (19.05–25.4 mm)1.001–1.500 in (25.43–38.1 mm)1.501–2.000 in (38.13–50.8 mm)2.001–2.500 in (50.83–63.5 mm)2.501–3.000 in (63.53–76.2 mm)3.001–4.000 in (76.23–101.6 mm)4.001–4.500 in (101.6–114.3 mm)4.501–5.000 in (114.3–127 mm)
SpecificationAMS 4200AMS 4200AMS 4200AMS 4200AMS 4200AMS 4200AMS 4200AMS 4200
BasisSSSSSSSS
Ftu, MPaL……496.4496.4489.5482.6468.8468.8
LT510.2503.3503.3503.3496.4482.6468.8468.8
ST……475.7475.7468.8448.2434.4434.4
Fty, MPaL……441.3434.4427.5413.7399.9399.9
LT448.2441.3441.3434.4427.5413.7399.9399.9
ST……406.8399.9393386.1372.3372.3
Fcy, MPaL……441.3434.4427.5413.7399.9…
LT……475.7468.8461.9441.3427.5…
ST……475.7468.8461.9441.3427.5…
Fsu, MPaL……282.7282.7282.7268.9262…
LT……282.7282.7282.7268.9262…
ST……282.7282.7282.7268.9262…
Fbru (e/D = 1.5), MPaL………786772.2751.5730.8…
LT………786772.2751.5730.8…
ST………786772.2751.5730.8…
Fbru (e/D = 2.0), MPaL………1007992.8965.3937.7…
LT………1007992.8965.3937.7…
ST………1007992.8965.3937.7…
Fbry (e/D = 1.5), MPaL………627.4613.6592.9572.3…
LT………627.4613.6592.9572.3…
ST………627.4613.6592.9572.3…
Fbry (e/D = 2.0), MPaL………730.8717.1696.4668.8…
LT………730.8717.1696.4668.8…
ST………730.8717.1696.4668.8…
e, %L……………665
LT88766555
ST……………222
E, GPa……69.6469.6469.6469.6469.6469.64
Ec, GPa……71.7171.7171.7171.7171.7171.71
G, GPa……26.8926.8926.8926.8926.8926.89
ν……0.330.330.330.330.330.33
ρ, kg/m³……285128512851285128512851

Effect of Temperature

Percent of the room-temperature value against temperature, digitized from the handbook figures (the shortest exposure of each figure, every 10 °F). Strength curves give the allowable at temperature; "after exposure" curves give the room-temperature property after a soak at that temperature.

Strength allowables at temperature, percent of room temperature

°CF_tuF_tyF_cy
3897.69999
938893.293.2
14974.480.680.6
20452.758.758.7

Factors in percent of the room-temperature allowable.

Source and Use

U.S. Department of Defense (2003). Metallic Materials and Elements for Aerospace Vehicle Structures. MIL-HDBK-5J, 31 January 2003 (public domain). The values are the handbook's design allowables as extracted from the chapter tables; check the printed table before use in a certified analysis, and note that MIL-HDBK-5J was superseded by MMPDS, whose later editions may differ. No warranty is given.