NIST e-Handbook 1.4.2.8.3: heat flow meter calibration data (ZARR13), summary and tests
| Tool | Data Summary and Outliers |
| Source | NIST/SEMATECH (2012). "Heat Flow Meter 1: Quantitative Output and Interpretation." e-Handbook of Statistical Methods. Section 1.4.2.8.3, data set ZARR13.DAT. |
| Level | Undergraduate |
Problem
Zarr's 195 calibration measurements of a heat flow meter (9.206343, 9.299992, 9.277895, …) are to be summarized: location and spread with their confidence intervals, lag-1 autocorrelation, a normality test and a check for an outlier at the 5 % level.
Inputs to Enter
- Column calibration, 195 values (loaded by default; a second illustrative column sample_b with a planted 14.9 is also loaded)
- Outlier level α = 0.05, max outliers 10
Answers
- Mean 9.261460, standard deviation 0.022789, 95 % interval of the SD 0.02073 to 0.025307; lag-1 autocorrelation 0.280579
- Grubbs G = 2.918673 (page; exact 2.918638) at row 46 (9.327973) against the critical value 3.597898, no outlier; the page labels the critical value one-tailed but it is the α/(2N) value
- Anderson–Darling adjusted A² = 0.129; normal PPCC 0.999 (the 0.996 of 1.4.2.8.3 is a stale figure, 1.4.2.8.4 prints 0.999); Shapiro–Wilk W 0.99827, p 0.9992
- Tukey inner fences 9.2029 and 9.3191; generalized ESD R1 = 2.9186 = Grubbs G, λ1 = 3.5979
Notes
The tool's default data set is this example; press Submit. Dixon's test is refused at n = 195. The chi-square critical value 7.815 and the t intervals follow the page.
More Examples for This Tool
- NIST e-Handbook 1.3.5.17.1: Grubbs' test on the Tietjen–Moore uranium data
- NIST e-Handbook 1.3.5.17.3: Rosner's generalized ESD test on 54 values
- Grubbs 1950: residuals of the semi-diameter of Venus (NIST 1.3.5.17.2)
- Shapiro and Wilk 1965: W test on the weights of eleven men
- Anscombe 1973: the quartet, four data sets with the same summary statistics