Tools › Fluids and Heat Transfer › Heat Exchangers › Heat Exchanger Sizing and Pressure Drop › Example

Water-to-water 1-2 shell-and-tube exchanger: energy balance, LMTD with the Bowman–Mueller–Nagle F, Kern shell side, shell sized to the area, both pressure drops

ToolHeat Exchanger Sizing and Pressure Drop
SourceBowman, R. A., Mueller, A. C., and Nagle, W. M. (1940). "Mean Temperature Difference in Design." Transactions of the ASME, Vol. 62, No. 4, pp. 283–294 (the 1-2 correction factor as mathematics); Kern, D. Q. (1950). Process Heat Transfer. McGraw-Hill, New York (shell-side method as mathematics, cited); U.S. Department of Energy (1992). DOE Fundamentals Handbook: Thermodynamics, Heat Transfer, and Fluid Flow, Volume 2 of 3. DOE-HDBK-1012/2-92 (LMTD and U_o examples used for the checks); Oak Ridge National Laboratory (1961). Heat Transfer and ΔP Design of MSRE Primary Heat Exchanger. ORNL CF-61-4-1; Segaser, C. L. (1952). Heat Exchanger Design Study for the ISHR. ORNL CF-52-10-195 (Kern shell-side pressure drops used for the checks).
LevelUndergraduate

Problem

Cool 50,000 lb/h of water from 180 to 120 °F with 100,000 lb/h of water entering at 60 °F in a 1-2 shell-and-tube exchanger with 3/4 in 16 BWG tubes on a 15/16 in triangular pitch, 12 ft long, two tube passes, cold water in the tubes, carbon-steel tubes, 0.0005 h·ft²·°F/Btu fouling on each side, baffles at half the shell diameter with 25 % cut, 10 % over-design and 10 lb/in² allowable on each side. Find the duty and the cold outlet, the LMTD and F, the film coefficients, U clean and fouled, the area required, the shell diameter and tube count that provide it, and the two pressure drops.

Inputs to Enter

  • Hot water 50,000 lb/h, 180 → 120 °F; cold water 100,000 lb/h, 60 °F in (outlet from the balance); water properties from IAPWS-IF97 at the mean bulk temperatures (150 °F and 75 °F)
  • 1 shell pass, 2 tube passes; 0.75 in OD × 0.065 in wall tubes, PR 1.25 triangular, L 12 ft, shell-to-bundle clearance 0.5 in, pass lane 0.625 in, k_w 26 Btu/(h·ft·°F), R_f 0.0005 h·ft²·°F/Btu each side, roughness 0.00006 in
  • Shell diameter, tube count and baffle spacing left blank (sized), B/D_s 0.5, cut 25 %, over-design target 10 %, allowable drops 10 lb/in² tube side and shell side, Dittus–Boelter in the tubes
Open the Heat Exchanger Sizing and Pressure Drop tool (loaded with this example)

Answers

  • C_h = 49,990 Btu/(h·°F), C_c = 99,900 Btu/(h·°F); Q = 2,999,000 Btu/h; cold outlet 90.02 °F
  • ΔT_1 = 89.98 °F, ΔT_2 = 60 °F, ΔT_lm = 73.98 °F; P = 0.2502, R = 1.999, F (Bowman 1-2 closed form) = 0.9420 (P_max for this R = 0.3822), F ΔT_lm = 69.69 °F
  • Tubes (cold water): 76 tubes in 2 passes, v = 5.60 ft/s, Re = 29,370, Dittus–Boelter Nu = 180.4, h_i = 1,220 Btu/(h·ft²·°F); shell (hot water, Kern): a_s = 0.0694 ft², G_s = 720,000 lb/(h·ft²), D_e = 0.542 in, Re_s = 31,300, h_o = 1,203 Btu/(h·ft²·°F)
  • U_clean = 487.4, U_fouled = 316.8 Btu/(h·ft²·°F); A_req = 135.8 ft² (clean 88.3 ft²); shell sized at 10 in ID with 76 tubes (lattice count; CTP/CL estimate 92), A_prov = 179.1 ft², over-surface 31.8 %; 27 baffles at 5 in
  • ΔP tube side = 2.34 + 1.69 (returns) = 4.02 lb/in² (within 10); ΔP shell side (Kern, f = 0.2489 at Re_s 31,300, 28 crossings) = 9.45 lb/in² (within 10)

Notes

The tool's default inputs are this case; press Submit. The case is illustrative (stated on the page), not a printed example; the method is checked by test_heat_exchanger_sizing.php (653 checks) against the DOE handbook's LMTD (232 °F) and U_o (827.6) examples, the ORNL MSRE memorandum (LMTD 137 °F, TEMA 1-2 factor 0.965, tube-side Re and ΔP), the ORNL ISHR memorandum (Kern crossflow areas, Reynolds numbers, friction-chart readings and nine shell-side pressure drops within 2 %), the Bowman closed forms against the ε–NTU route and an independent numpy script, and Mason's crossflow series against a 2-D cell solution.